Omron G2R-1-E-12V PCB Mount Relay 12Vdc 1 CO, SPDT G2R-1-E-12V データシート

製品コード
G2R-1-E-12V
ページ / 14
6
G2R
PCB Power Relay
G
2
R
Characteristics
● Standard Relays
Note: The values here are initial values.
*1.
Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2.
Measurement conditions: Rated operating voltage applied, not including 
contact bounce.
*3.
Measurement conditions: The insulation resistance was measured with a 
500 VDC megohmmeter at the same locations as the dielectric strength 
was measured.
*4.
Value for quick-connect terminals.
Double-winding Latching Relays
Note: The values here are initial values.
*1.
Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2.
Measurement conditions: Rated operating voltage applied, not including 
contact bounce.
*3.
Measurement conditions: The insulation resistance was measured with a 
500 VDC megohmmeter at the same locations as the dielectric strength 
was measured.
Engineering Data
Item
Number of poles
1-pole
2-pole
Contact resistance *1
30 m
Ω max.
50 m
Ω max.
Operate time *2
15 ms max.
Release time *2
AC: 10 ms max.; DC: 5 ms max.
Max. 
operating 
frequency
Mechanical
18,000 operations/hr
Electrical
1,800 operations/hr
Insulation resistance *3
1,000 M
Ω min.
Dielectric 
strength
Between coil and 
contacts
5,000 VAC, 50/60 Hz for 1 min 
Between contacts 
of different polarity
-
3,000 VAC, 50/60 Hz 
for 1 min 
Between contacts 
of the same 
polarity
1,000 VAC, 50/60 Hz for 1 min 
Vibration 
resistance
Destruction
10 to 55 to 10 Hz, 0.75 mm single 
amplitude (1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single 
amplitude (1.5 mm double amplitude)
Shock 
resistance
Destruction
1,000 m/s
2
Malfunction
200 m/s
2
 when energized; 
100m/s
2
 when no energized
Durability
Mechanical
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. 
(at 18,000 operations/hr)
Electrical
100,000 operations min. 
(at 1,800 operations/hr under rated load)
Ambient operating temperature
-40°C to 70°C (with no icing)
Ambient operating humidity
5% to 85%
Weight
Approx. 17 g (Approx. 20 g *4)
Item
Number of poles
1-pole
2-pole
Contact resistance *1
30 m
Ω max.
50 m
Ω max.
Set
Time *2
20 ms max.
Min. set pulse width
30 ms
Reset
Time *2
20 ms max.
Min. reset pulse 
width
30 ms
Max. operating 
frequency
Mechanical
18,000 operations/hr
Electrical
1,800 operations/hr
Insulation resistance *3
1,000 M
Ω min. (at 500 VDC)
Dielectric 
strength
Between coil and 
contacts
5,000 VAC, 50/60 Hz for 1 min
Between contacts 
of different polarity
3,000 VAC, 
50/60 Hz for 1 min
Between contacts 
of the same 
polarity
1,000 VAC, 50/60 Hz for 1 min
Between set and 
reset coils
1,000 VAC, 50/60 Hz for 1 min
Vibration 
resistance
Destruction
10 to 55 to 10 Hz, 0.75 mm single 
amplitude (1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single 
amplitude (1.5 mm double amplitude)
Shock 
resistance
Destruction
1,000 m/s
2
Malfunction
Set: 500m/s
2
 Armature OFF
Reset: 200m/s
2
 Contact OFF
Durability
Mechanical
10,000,000 operations min 
(at 18,000 operations/hr)
Electrical
100,000 operations min. (at 1,800 
operations/hr under rated load)
Ambient operating temperature
-40°C to 70°C (with no icing or 
condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 17 g
● Maximum Switching Capacity
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T
G2R-1-E, G2R-1A-E
G2R-1Z, G2R-1AZ
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A
G2R-2-H, G2R-2A-H
Flux Protection/Plug-in Relays
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 
10 
20 
30 
50 
100 
500
AC resistive load
DC resistive load
AC
inductive load
(cos
φ = 0.4)
DC inductive load
(L/R = 7 ms)
Switching current (A)
AC
inductive load
(cos
φ = 0.4)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 
10 
20 
30 
50 
100 
500
16
DC resistive load
AC resistive load
DC inductive load
(L/R = 7 ms)
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 
10 
20 
30 
50 
100 
500
AC resistive load
DC resistive load
DC inductive load
(L/R = 7 ms)
AC
inductive load
(cos
φ = 0.4)
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 
10 
20 
30 
50 
100 
500
AC
inductive load
(cos
φ = 0.4)
DC inductive load
(L/R = 7 ms)
DC resistive load
AC resistive load
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 
10 
20 
30 
50 
100 
500
AC resistive load
AC
inductive load
(cos
φ = 0.4)
DC resistive load
DC inductive load
(L/R = 7 ms)