Panasonic APF30324V PCB Mount Relay APF30324 データシート

製品コード
APF30324
ページ / 5
PF (APF)
4
ds_61C16_en_pf: 070313D
DIMENSIONS 
(mm 
inch
)
SAFETY STANDARDS
NOTES
Certification 
authority
File No.
Applicable standard
Rating
Remarks
UL, C-UL
E120782
UL508, CSA C22.2  No.14
UL1604 (class I, Division 2, Group A, B, C, D)
277V AC 8A, General use,
24V DC 6A, General use,
B300, R300 (Pilot Duty)
VDE
40027672
EN/IEC 61810-1
250V AC 6A (cos
 = 1.0) 85C 
185
F
N.O. side, N.C. side
250V AC 8A (cos
 = 1.0) 25C 
77
F
N.O. side
Insulation: Reinforced insulation between contact 
and coil.
Resistance to heat and fire; EN60335-1, clause 
30 (GWT) approved.
1. 1 Form A type
External dimensions
General tolerance: 
0.3 
.012
0.4
.016
1.2
.047
3.78
.149
2-0.6
2-.024
28.0max.
1.102max.
21.42
.843
2-1.0
2-.039
5.04
.198
1.9
.075
0.5
.020
15.0max.
.591max.
3.5
±
0.5
.138
±
.020
5.0max.
.197max.
1.2
.047
0.48
.019
PC board pattern (Bottom view)
Tolerance: 
0.1 
.004
Schematic (Bottom view)
3.78
.149
21.42
.843
5.04
.198
1.9
.075
1.2
.047
2-1.0 dia.
2-.039 dia.
2-1.3 dia.
2-.051 dia.
NO
COM
COIL
2. 1 Form C type
External dimensions
General tolerance: 
0.3 
.012
0.4
.016
1.2
.047
2-0.6
2-.024
21.42
.843
3-1.0
3-.039
0.5
.020
3.5
±
0.5
.138
±
.020
5.0max.
.197max.
1.2
.047
0.48
.019
3.78
.149
1.9
.075
28.0max.
1.102max.
5.04
.198
5.04
.198
15.0max.
.591max.
PC board pattern (Bottom view)
Tolerance: 
0.1 
.004
Schematic (Bottom view)
3.78
.149
21.42
.843
5.04
.198
5.04
.198
1.9
.075
1.2
.047
2-1.0 dia.
2-.039 dia.
3-1.3 dia.
3-.051 dia.
NO
COM
NC
COIL
 Usage, transport and storage 
conditions
1) Temperature: 
–40 to +85
C 
–40 to +185
F
2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the 
temperature. Use within the range 
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for 
usage, transport, and storage
4) Condensation
Condensation forms when there is a 
sudden change in temperature under 
high temperature and high humidity 
conditions. Condensation will cause 
deterioration of the relay insulation.
5) Freezing
Condensation or other moisture may 
freeze on the relay when the 
temperatures is lower than 0
C 
32
F
This causes problems such as sticking of 
movable parts or operational time lags.
6) Low temperature, low humidity 
environments
The plastic becomes brittle if the relay is 
exposed to a low temperature, low 
humidity environment for long periods of 
time.
85
5
Humidity, %RH
Tolerance range
(Avoid
condensation 
when used at 
temperatures 
higher than 
0
°
C
32
°
F
)
(Avoid freezing 
when used at 
temperatures 
lower than 
0
°
C
32
°
F
)
85
0
-40
+185
+32
-40
Temperature, 
°
C
°