Omron G5Q-1A-EU 5DC PCB Mount Power Relay 5Vdc 1 NO, SPST-NO G5Q-1A-EU 5DC データシート

製品コード
G5Q-1A-EU 5DC
ページ / 4
G5Q-EU
G5Q-EU
Contact Rating
Characteristics
Load
SPDT
SPDT-NO
Rated load (resistive)
10A at 250 VAC (NO)
10A at 250 VAC
3A at 250 VAC (NO)
3A at 250 VAC
3A at 125 VAC (NO)
3A at 125 VAC
5A at 30 VDC (NO)
5A at 30 VDC
3A at 250 VDC (NC)
3A at 125 VDC (NC)
3A at 30 VDC (NC)
Contact material
Ag Alloy
Rated carry current
AC 10 A – DC 5A (NO)/ AC 3A – DC 3A (NC)
Max. switching voltage
277 VAC, 30 VDC
Max. switching current
AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)
Max. switching capacity
2500 VA, 150 W (NO)
750 VA, 90 W (NC)
Min. permissible load
10 mA at 5 VDC (P level:
λ
60 = 0.1 x 10
-6
operation)
Contact resistance (see note 2)
100 m
Ω
max.
Operate time
10 ms max.
Release time
5 ms max.
Insulation resistance (see note 3)
1,000 M
Ω
min.
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
8 kV (1.2 x 50 ms) between coil and contacts
Vibration resistance 
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes
Shock resistance
Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: 100 m/s
2
(approximately 10G)
Life expectancy (see note 4)
Mechanical 10,000,000 operations (18,000 operations per hour)
Electrical 200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC resistive load
100,000 operations: 3 A (NO)/3 A (NC) at 250 VAC
5 A (NO)/3 A (NC) at 30 VDC resistive load
25,000 operations: 10A (NO) at 250 VAC (900 operations per hour: 
1 sec ON/3 sec OFF)
Switching frequency: 1,800 operations per hour: 1 sec ON/1 SEC OFF
Ambient temperature
Operating & storage: -40°C to 85°C (with no icing)
Ambient humidity
Operating & storage: 5% to 85%
Note: 1. The data shown above are initial value.
2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
4. The electrical life data items shown are possible at 23°C.