Omron G6RL-14-ASI 5 VDC PCB Mount Relay 5Vdc 1 CO, SPDT G6RL-14-ASI 5 VDC データシート

製品コード
G6RL-14-ASI 5 VDC
ページ / 8
5
G6RL
G6RL
Electrical Endurance Data
Endurance Under Real Load 
G6RL-1(A)-ASI-PL
Note:
The results shown reflect values measured using very sever test conditions, i.e., Duty:  1 s ON/OFF.
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed
information for the electrical endurance under your test conditions.
G6RL-1(A)
8 A at 250 VAC (cos
φ = 1) NO  50,000 operations min.
8 A at 250 VAC (cos
φ = 1) NC  50,000 operations min.
5 A at 24 VDC
 50,000 operations min.
G6RL-1(A)-(SR)-ASI-(PL)
10 A at 250 VAC (cos
φ = 1) NO 100,000 operations min.
8 A at 250 VAC (cos
φ = 1)
100,000 operations min.
5 A at 30 VDC
 50,000 operations min.
G6RL-1(A)4-ASI
8 A at 250 VAC (cos
φ = 1) NO  50,000 operations min.
8 A at 250 VAC (cos
φ = 1) NC  50,000 operations min.
5 A at 24 VDC
 50,000 operations min.
G6RL-14-SR-ASI
8 A at 250 VAC (cos
φ = 1) NO  50,000 operations min.
3 A at 250 VAC (cos
φ = 1) NC  100,000 operations min.
5 A at 24 VDC NO
 50,000 operations min.
5 A at 24 VDC NC
 30,000 operations min.
(Reference Only)
Rated voltage
Condition
Frequency
Electrical life
230 VAC
P1 load (2 
× 200 W lamps parallel to ignition transformer)
1.5 s ON/4.5 s OFF
250,000 operations