Omron G6B-1114P-US 24 VDC PCB Mount Power Relay 24Vdc 1 NO, SPST-NO G6B-1114P-US 24 VDC データシート

製品コード
G6B-1114P-US 24 VDC
ページ / 7
174
G6B
G6B
Accessories (Order Separately)
Back Connecting Sockets
*Not applicable to the self-clinching type.
Specifications
Coil Ratings
Single-side Stable Type
Single-winding Latching Type
Double-winding Latching Type
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
Applicable relay
Back connecting socket*
G6B(U)-1114P-US
P6B-04P
G6BK-1114P-US
P6B-06P
G6B-2
@@4P-US-P6B
P6B-26P
G6B-1174P-US
P6B-04P
Removal Tool
P6B-Y1
Hold-down Clips
P6B-C2
Item
SPST-NO
SPST-NO + SPST-NC, DPST-NO, DPST-NC
Rated voltage (VDC)
5
6
12
24
5
6
12
24
Rated current (mA)
40
33.3
16.7
8.3
60
50
25
12.5
Coil resistance (
Ω)
125
180
720
2,880
83.3
120
480
1,920
Coil inductance
(H) (ref. value)
Armature OFF
0.28
0.31
1.2
4.9
---
---
---
---
Armature ON
0.26
0.28
1.1
4.1
---
---
---
---
Must operate voltage
70% max. of rated voltage
80% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
160% of rated voltage (at 23
°C)
140% of rated voltage (at 23
°C)
Power consumption
Approx. 200 mW
Approx. 300 mW
Rated voltage
5 VDC
6 VDC
12 VDC
24 VDC
Rated current
40 mA
33.3 mA
16.7 mA
8.3 mA
Coil resistance
125 
Ω
180 
Ω
720 
Ω
2,880 
Ω
Coil inductance
(H) (ref. value)
Armature OFF
0.28
0.31
1.2
4.9
Armature ON
0.26
0.28
1.1
4.1
Must operate voltage
70% max. of rated voltage
Must release voltage
70% min. of rated voltage
Max. voltage
160% of rated voltage (at 23
°C)
Power consumption
Approx. 200 mW
Rated voltage
5 VDC
6 VDC
12 VDC
24 VDC
Set coil
Rated current
56 mA
46.8 mA
23.3 mA
11.7 mA
Coil resistance
89.2 
Ω
128.5 
Ω
515 
Ω
2,060 
Ω
Coil inductance
(H) (ref. value)
Armature OFF
0.15
0.18
0.52
1.2
Armature ON
0.15
0.18
0.52
1.2
Reset coil Rated current
56 mA
46.8 mA
23.3 mA
11.7 mA
Coil resistance
89.2 
Ω
128.5 
Ω
515 
Ω
2,060 
Ω
Coil inductance
(H) (ref. value)
Armature OFF
0.15
0.18
0.52
1.2
Armature ON
0.15
0.18
0.52
1.2
Must set voltage
70% max. of rated voltage
Must reset voltage
70% min. of rated voltage
Max. voltage
130% of rated voltage (at 23
°C)
Power consumption
Set coil: Approx. 280 mW