Omron G6B-1114P-US 24 VDC PCB Mount Power Relay 24Vdc 1 NO, SPST-NO G6B-1114P-US 24 VDC データシート

製品コード
G6B-1114P-US 24 VDC
ページ / 7
176
G6B
G6B
Approved Standards
UL508 (File No. E41643)/CSA C22.2 No.14 (File No. LR31928)
Engineering Data
Model
Contact form
Coil rating
Contact rating
G6B-1114P-US
G6B-1114C-US
G6BU-1114P-US
G6BU-1114C-US
G6BK-1114C-US
G6BK-1114C-US
SPST-NO
3 to 24 VDC
5 A, 250 VAC (general use)
5 A, 30 VDC (resistive load)
G6B-1174P-US
G6B-1174C-US
8 A, 250 VAC (general use)
8 A, 30 VDC (resistive load)
G6B-2114P-US
G6B-2114C-US
G6B-2214P-US
G6B-2214C-US
G6B-2014P-US
G6B-2014C-US
SPST-NO + SPST-NC
DPST-NO
DPST-NC
5 A, 250 VAC (general use)
5 A, 30 VDC (resistive load)
G6B-1114P(C)-US
250 VAC/30 VDC 
inductive load
(cos
φ = 0.4, L/R = 7 ms)
G6B-1174P(C)-US
250 VAC/30 VDC 
resistive load
G6B-1114P(C)-US
250 VAC/30 VDC resistive load
G6B-1114P-US
Maximum Switching Power
Switching voltage (V)
Endurance
Ambient Temperature  vs. 
Maximum Coil Voltage
G6B-2114P-US, G6B-2214P-US 
G6B-2014P-US
Maximum Switching Power
Endurance
Endur
ance (x10   oper
ations)
3
Switching current (A)
Maxim
um coil v
oltage (%)
Endur
ance (x10   oper
ations)
3
Switching current (A)
Ambient temperature (
°C)
Switching voltage (V)
Switching current (A)
Switching current (A)
AC resistive load
AC inductive load 
(cos
φ = 0.4)
DC inductive load 
(L/R = 7 ms)
DC resistive load
AC inductive load 
(cos
φ = 0.4)
AC resistive 
load
DC resistive load
DC inductive load 
(L/R = 7 ms)
G6B-2114P-US
G6B-2214P-US
G6B-2014P-US
G6B-1174P-US
G6B-1114P-US
250 VAC inductive load (cos
φ = 0.4)
30 VDC inductive load (L/R = 7 ms)
250 VAC resistive load
30 VDC resistive load
Note:   The maximum coil voltage refers 
to the maxi-mum value in a 
varying range of operating power 
voltage, not a continuous voltage.