Omron G5RL-1-E-HR 12 VDC PCB Mount Power Relay 12Vdc 1 CO, SPDT G5RL-1-E-HR 12 VDC データシート
製品コード
G5RL-1-E-HR 12 VDC
139
Text
138
Text
PCB Power Relay – G5RL
Dimensions
Note: All units are in millimetres unless otherwise indicated.
20
3.5
0.5
× 0.5
0.33
0.43
7.5
1
3.5
29.0 max.
(28.8)
∗
15.7 max.
(15.5)
(15.5)
∗
12.7max.
(12.5)
∗
7.5
±0.1
20
±0.1
3.5
±0.1
(2.3)
* Indicates average
dimensions.
dimensions.
Four, 1.3
±0.1
dia.
3
1
5
4
Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
Internal Connections
(Bottom View)
■
Approved Standards
UL 508 (File No. E41643)/CSA C22.2 (No.14) (File No. LR31928)
Models with AC Coil
Model
Coil ratings
Contact ratings
G5RL-1-E
24 to 240 VAC
16 A, 277 VAC General, 50,000 operations - NO
16 A, 250 VAC General, 50,000 operations - NO
TV-5, 25,000 operations - NO
A300 Pilot Duty, 720 VA, 240 VAC, 30,000 operations - NO
1/2 Hp, 120 VAC, 6,000 operations - NO
60 LRA/10 FLA, 250 VAC, 6,000 operations - NO
5 A, 250 VAC General, 50,000 operations - NC
5 A, 24 VDC Resistive, 50,000 operations - NC
16 A, 250 VAC General, 50,000 operations - NO
TV-5, 25,000 operations - NO
A300 Pilot Duty, 720 VA, 240 VAC, 30,000 operations - NO
1/2 Hp, 120 VAC, 6,000 operations - NO
60 LRA/10 FLA, 250 VAC, 6,000 operations - NO
5 A, 250 VAC General, 50,000 operations - NC
5 A, 24 VDC Resistive, 50,000 operations - NC
VDE (EN61810-1) (License No. A282)
Model
Coil ratings
Contact ratings
G5RL-1-E
24, 100, 115/120, 200, 230/240 VAC (50 Hz)
16 A, 250 VAC 15,000 operations - NO
G5RL-1-E
PCB Power Relay – G5RL
Power Relays
Contact form
SPDT
Contact material
Ag alloy (Cd free)
Load
Resistive load (cosφ=1)
Rated load
16 A at 250 VAC (NO)
16 A at 24 VDC (NO)
5 A at 250 VAC (NC)
5 A at 24 VDC (NC)
16 A at 24 VDC (NO)
5 A at 250 VAC (NC)
5 A at 24 VDC (NC)
Rated carry current
16 A (NO), 5 A (NC)
Max. switching voltage
250 VAC, 24 VDC
Max. switching current
16 A (NO), 5 A (NC)
Max. switching power
4,000 VA, 384 W (NO)
1,250 VA, 120 W (NC)
1,250 VA, 120 W (NC)
Failure rate (reference value)
40 mA at 24 VDC
Note: P level: λ60 = 0.1 x 10
–6
operations
Note: 1. Values in the above table are initial values.
2. The contact resistance is measured with 1 A applied at
5 VDC using a fall-of-potential method.
3. The insulation resistance is measured between coil
and contacts and between contacts of the same
polarity at 500 VDC.
polarity at 500 VDC.
■
Coil Ratings
■
Coil Ratings
Contact resistance
100 mΩ max.
Operate time
20 ms max.
Release time
20 ms max.
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
16 A (NO), 5 A (NC)
Max. switching voltage
6,000 VAC, 50/60 Hz for 1 min
between coil and contacts 1,000
VAC, 50/60 Hz for 1 min between
contacts of same polarity
between coil and contacts 1,000
VAC, 50/60 Hz for 1 min between
contacts of same polarity
Impulse withstand
10 kV between coil and contacts
voltage
(1.2 x 50 µs)
Vibration resistance
Destruction: 10 to 55 to 10 Hz,
1.5-mm double
amplitude
amplitude
Malfunction: 10 to 55 to 10 Hz,
1.5-mm double
amplitude
amplitude
Endurance
Mechanical: 10,000,000 operations
min. (at 18,000
operations/h)
operations/h)
Electrical:
50,000 operations min.
(Resistive load, 16 A,
250 VAC, NO contact)
(Resistive load, 16 A, 24
VDC, NO contact)
(Resistive load, 5 A,
250 VAC, NC contact)
(Resistive load, 5 A,
24 VDC, NC contact)
(Resistive load, 16 A,
250 VAC, NO contact)
(Resistive load, 16 A, 24
VDC, NO contact)
(Resistive load, 5 A,
250 VAC, NC contact)
(Resistive load, 5 A,
24 VDC, NC contact)
Ambient temperature
Operating: -40°C to 70°C
(with no icing)
(with no icing)
Ambient humidity
Operating: 5% to 85%
Weight
Approx. 10g
■
Characteristics
Rated voltage
24 VAC
100 VAC
115 VAC / 120 VAC
200 VAC
230 VAC / 240 VAC
Rated current 50Hz (mA)
31.30 mA
7.50 mA
5.85 mA
6.25 mA
3.75 mA
3.00 mA
3.13 mA
Rated current 60Hz (mA)
28.30 mA
6.88 mA
5.35 mA
5.70 mA
3.45 mA
2.76 mA
2.88 mA
Coil resistance
443Ω
8,220Ω
11,600Ω
33,000Ω
47,600Ω
Must operate voltage
75% max. of rated voltage
Must release voltage
15% min. of rated voltage
Max. voltage
90% to 110% of rated voltage
Power consumption
Approx. 0.75 VA
Note: 1. The above items are measured at a coil temperature of 23˚C.
2. The tolerance of rated current is +15% / -20%.
3. Power consumption drop was measured at 50Hz.
4. Coil resistance is provided as reference values.
Specifications
Omron 08 Cat 1-302 5/10/07 15:39 Page 138