Omron G6K-2F-Y 12DC PCB Mount Signal Relay 12Vdc 2 CO, Monostable G6K-2F-Y 12DC データシート

製品コード
G6K-2F-Y 12DC
ページ / 12
G6K
G6K
3
Single-winding Latching Models (Bellcore Version)
G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y
Rated voltage
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
Rated current
33.0 mA
23.2 mA
21.1 mA
9.1 mA
4.6 mA
Coil resistance
91 
Ω
194 
Ω
237 
Ω
1,315 
Ω
5,220 
Ω
Must set voltage
75% max. of rated voltage
Must reset voltage
75% max. of rated voltage
Max. voltage
150% of rated voltage at 23
°
C to 70
°
C
Power consumption
Approx. 100 mW
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of 
±
10%.
2. The operating characteristics are measured at a coil temperature of 23
°
C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
 Contact Ratings
Load
Resistive load
Rated load
0.3 A at 125 VAC; 1 A at 30 VDC
Rated carry current
1 A
Max. switching voltage
125 VAC, 60 VDC
Max. switching current
1 A
 Characteristics
Item
Single-side stable models (double-pole)
Single-winding latching
model
G6K-2F, G6K-2G, G6K-2P
G6K-2F-Y, G6K-2G-Y,
G6K-2P-Y
G6KU-2F-Y, G6KU-2G-Y,
G6KU-2P-Y
Contact resistance (see note 1)
100 m
Ω
 max.
Operating (set) time (see note 2)
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.2 ms)
Release (reset) time (see note 2)
3 ms max. (approx. 1.3 ms)
3 ms max. (approx. 1.2 ms)
Insulation resistance (see note 3)
1,000 M
Ω
 min. (at 500 VDC)
Dielectric
t
th
Coil and contacts
1,500 VAC, 50/60 Hz for 1 min
e ec
c
strength
Contacts of different
polarity
1,000 VAC, 50/60 Hz for 1 min
Contacts of same
polarity
750 VAC, 50/60 Hz for 1 min
Impulse
ith t
d
Coil and contacts
1,500 V, 10 x 160 
µ
s
2,500 V, 2 x 10 
µ
s, 1,500 V, 10 x 160 
µ
s
pu se
withstand
voltage
Contacts of different
polarity
1,500 V, 10 x 160 
µ
s
Contacts of same
polarity
Vibration resistance
Destruction:
0 to 55 Hz, 5-mm double amplitude and 55 to 500 Hz, 300 m/s
2
 (approx. 30G)
Malfunction: 10 to 55 Hz, 3.3-mm double amplitude and 55 to 500 Hz, 200 m/s
2
 (approx. 20G)
Shock resistance
Destruction:
1,000 ms
2
 (approx. 100G)
Malfunction: 750 ms
2
 (approx. 75G)
Life expectancy
Mechanical:
50,000,000 operations min. (at 36,000 operations/hour)
Electrical:
100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level) (see note 4)
10 
µ
A at 10 mVDC
Ambient temperature
Operating:
–40
°
C to 70
°
C (with no icing or condensation)
Storage:
–40
°
C to 70
°
C (with no icing or condensation)
Ambient humidity
Operating:
35 to 85%
Weight
Approx. 0.7 g
Note:
The above values are initial values.
Note:
1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megger applied to the same parts as those used for checking the dielectric
strength.
4. This value was measured at a switching frequency of 120 operations/min.