Omron G6K-2F-Y 5DC PCB Mount Signal Relay 5Vdc 2 CO, Monostable G6K-2F-Y 5DC データシート

製品コード
G6K-2F-Y 5DC
ページ / 12
G6K
G6K
2
Model Number Legend
G6K-
j
-
jj
-
jj
 VDC
1
2
3
4
5
1.
Relay function
None:
Single-side stable model
U:
Single-winding latching model
2.
Contact form
2:
DPDT
3.
Terminal shape
F:
Outside-L surface-mounting terminal
G:
Inside-L surface-mounting terminal
P:
PCB terminal
4.
Approved standards
None:
UL, CSA
Does not conform to Bellcore specifications
Y:
UL, CSA
Conforms to Bellcore specifications: 2,500 V for 2 x 10 
µ
s
5.
Rated coil voltage (Refer to 
Coil Ratings)
Application Examples
Telephones, communications equipment, measurement devices, office automation machines, and audio-visual products.
Specifications
Contact mechanism:
Crossbar twin Ag (Au-alloy contact)
Enclosure rating:
Plastic-sealed
 Coil Ratings
Single-side Stable Models
G6K-2F, G6K-2G, G6K-2P
Rated voltage
3 VDC
4.5 VDC
5 VDC
12 VDC
Rated current
33.0 mA
23.2 mA
21.1 mA
9.1 mA
Coil resistance
91 
Ω
194 
Ω
237 
Ω
1,315 
Ω
Must operate voltage
80% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
150% of rated voltage at 23
°
C to 70
°
C
Power consumption
Approx. 100 mW
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of 
±
10%.
2. The operating characteristics are measured at a coil temperature of 23
°
C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
Single-side Stable Models (Bellcore Version)
G6K-2F-Y, G6K-2G-Y, G6K-2P-Y
Rated voltage
3 VDC
4.5 VDC
5 VDC
12 VDC
24 VDC
Rated current
33.0 mA
23.2 mA
21.1 mA
9.1 mA
4.6 mA
Coil resistance
91 
Ω
194 
Ω
237 
Ω
1,315 
Ω
5,220 
Ω
Must operate voltage
80% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
150% of rated voltage at 23
°
C to 70
°
C
Power consumption
Approx. 100 mW
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of 
±
10%.
2. The operating characteristics are measured at a coil temperature of 23
°
C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.