Vision Akkus VISION 6FM150DX, 12V Ah lead acid battery 6FM150DX 6FM150DX データシート

製品コード
6FM150DX
ページ / 2
6FM150D-X
12V 150Ah(10hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid 
electrolyte is absorbed by separators and plates and thus immobilized. Should the 
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up. 
Otherwise, the battery is completely sealed and is, therefore, maintenance-free, 
leak proof and usable in any position. 
Battery Construction
Component
Positive plate
Negative plate
Container
Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Copper
Fiberglass
Sulfuric acid
General Features 
Absorbent Glass Mat (AGM) technology 
for efficient gas recombination of up to 
99% and freedom from electrolyte 
maintenance or water adding.
Not restricted for air transport-complies 
with IATA/ICAO Special Provision A67.
UL-recognized component.
Can be mounted in any orientation.
Computer designed lead, calcium tin alloy 
grid for high power density.
Long service life, float or cyclic 
applications.
Maintenance-free operation.
Low self discharge.
Dimensions and Weight
Length(mm / inch)
485 / 19.09
Width(mm / inch)
172 / 6.77
Height(mm / inch) 
240 / 9.45
Total Height(mm / inch) 
240 / 9.45
Approx. Weight(Kg / lbs) 
47 / 103.6 
Performance Characteristics 
Nominal Voltage
12V
Number of cell
6
Design Life 
10 years 
Nominal Capacity 77
o
F(25
o
C)
20 hour rate (7.5A, 10.5V)
150Ah
10 hour rate (14.3A, 10.5V)
143Ah
5 hour rate (24.9A, 10.5V)
124.5Ah
1 hour rate (96A, 9.6V)
96Ah
Internal Resistance
Fully Charged battery 77
o
F(25
o
C)
3.7mOhms
Self-Discharge
3% of capacity declined per month at 20
o
C(average)
Operating Temperature Range
Discharge
-20~60
o
C
Charge
-10~60
o
C
Storage
-20~60
o
C
Max. Discharge Current 77
o
F(25
o
C)
1000A(5s)
Short Circuit Current
2700A
Charge Methods: Constant Voltage Charge 77
o
F(25
o
C)
Cycle use
14.4-14.7V
        Maximum charging current
45A
        Temperature compensation 
-30mV/
o
C
Standby use 
13.6-13.8V
        Temperature compensation 
-20mV/
o
C
Discharge Constant Current (Amperes at 77
o
F25
o
C)
Discharge Constant Power (Watts at 77
o
F25
o
C)
page1 of 2
www.vision-batt.com
(Note)The above characteristics data are average values obtained within 
three charge/discharge cycles not the mimimum values.
End Point
Volts/cell
5min 10min 15min 30min
1h
3h
5h
10h
20h
100h
1.60V
440
343
279
160
101
40.7
27.7
15.9
8.15
1.81
1.65V
409
322
263
156
98.7
39.8
27.3
15.7
8.08
1.80
1.70V
379
302
251
152
96.7
38.9
26.7
15.4
7.98
1.78
1.75V
348
282
236
146
93.8
38.2
26.1
15.2
7.87
1.76
1.80V
313
259
222
143
90.7
37.0
25.7
15.0
7.74
1.74
End Point
Volts/cell
5min 10min 15min 30min 45min
1h
2h
3h
5h
100h
1.60V
751
598
492
320
218
198
111
77.8
53.4
3.60
1.65V
721
569
474
309
214
195
109
76.9
53.1
3.59
1.70V
673
538
457
300
209
192
107
75.9
52.7
3.58
1.75V
627
510
437
291
203
187
105
75.0
52.3
3.57
1.80V
577
478
417
281
199
181
104
73.8
51.8
3.56