Vision Akkus VISION 6FM100DX, 12V Ah lead acid battery 6FM100P-X 6FM100P-X データシート

製品コード
6FM100P-X
ページ / 2
 
 
 
6FM100P-X
   
12V 100Ah(10hr)
 
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid 
electrolyte is absorbed by separators and plates and thus immobilized. Should the 
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up. 
Otherwise, the battery is completely sealed and is, therefore, maintenance-free, 
leak proof and usable in any position. 
 
Battery Construction
Component
Positive plate
Negative plate
Container
Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Copper
Fiberglass
Sulfuric acid
General Features 
●     
Advanced pure lead technology.
●     
Stronger discharge performance. 
Excellent consistency and reliability.
●      
Special design to avoid thermal runaway.
     
Can be mounted in any orientation.
     
Longer float & cycle life, longer warranty.
●     
Maintenance-free operation.
●     
Low self discharge.
Dimensions and Weight
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
page1 of 2
 
www.vision-batt.com
 
                    
                                             
                          
Length(mm / inch)
339 / 13.35
Width(mm / inch)
173 / 6.81
Height(mm / inch) 
214.5 / 8.44
Total Height(mm / inch) 
220 / 8.66
Approx. Weight(Kg / lbs) 
27.5 / 60.6
Performance Characteristics 
Nominal Voltage
12V
Number of cell
6
Nominal Capacity 77
o
F(25
o
C)
10 hour rate (10.0A, 10.8V)
100Ah
5 hour rate (17.5A, 10.5V)
87.5
.
Ah
1 hour rate (66.2A, 9.6V)
66.2 Ah
Internal Resistance
Fully Charged battery 77
o
F(25
o
C)
5.7mOhms
Self-Discharge
3% of capacity declined per month at 20
o
C(average)
Operating Temperature Range
Discharge
-20~60
o
C
Charge
-10~60
o
C
Storage
-20~60
o
C
Max. Discharge Current 77
o
F(25
o
C)
900A(5s)
Short Circuit Current
2500A
Charge Methods: Constant Voltage Charge 77
o
F(25
o
C)
Cycle use
        Maximum charging current
30A
        Temperature compensation 
-30mV/
o
C
Standby use 
        Temperature compensation 
-20mV/
o
C
Discharge Constant Current (Amperes at 77
o
F25
o
C)
Discharge Constant Power (Watts at 77
o
F25
o
C)
(Note)The above characteristics data are average values obtained within 
three charge/discharge cycles not the mimimum values.
End Point
Volts/Cell
10min
15min
30min
1h
3h
5h
10h
20h
1.60V
229
185
108
66.2
27.9
19.0
10.8
5.50
1.65V
221
178
104
62.5
27.7
18.3
10.6
5.45
1.70V
200
164
96.0
61.5
27.2
18.0
10.5
5.40
1.75V
187
153
93.0
60.5
26.9
17.5
10.3
5.35
1.80V
175
143
91.0
57.4
25.3
17.2
10.0
5.30
End Point
Volts/Cell
10min
15min
30min
45min
1h
10h
3h
5h
1.60V
392
321
199
150
124
20.3
52.8
35.8
1.65V
379
315
188
146
118
20.1
51.2
35.4
1.70V
360
299
183
137
114
20.0
50.9
35.0
1.75V
353
294
177
134
111
19.6
49.1
34.4
1.80V
329
279
171
131
104
19.1
48.5
34.0
2.40-2.45VPC
2.20-2.30VPC
5min
314
296
270
242
221
5min
547
517
478
441
415
Design Life 
10 years 
339±1
173±1
214.5±1
220±1
44
266
16
M8
5
     
●     
Case and cover avaiable in both standard 