 Characteristics
Item
Standard models
High sensitivity models
Contact resistance
50 m
Ω
 max.
100 m
Ω
 max.
Operate time
7 ms max.
Release time
3 ms max.
Bounce time
Operate: approx. 0.3 ms
Release: approx. 1.5 ms
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
Ω
 min. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between
contacts of different polarity
750 VAC, 50/60 Hz for 1 min between
contacts of same polarity
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between
contacts of different polarity
500 VAC, 50/60 Hz for 1 min between
contacts of same polarity
Impulse withstand voltage
1,500 V 10 x 160 
µ
s between coil and contacts (conforms to FCC Part 68)
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
 (approx. 100G)
Malfunction: 200 m/s
2
 (approx. 20G)
Destruction: 1,000 m/s
2
 (approx. 100G)
Malfunction: 100 m/s
2
 (approx. 10G)
Life expectancy
Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr)
Ambient temperature
Operating: –25
°
C to 65
°
C (with no icing)
Storage:
–25
°
C to 65
°
C (with no icing)
Operating: –25
°
C to 70
°
C (with no icing)
Storage:
–40
°
C to 70
°
C (with no icing)
Ambient humidity
Operating: 35% to 85%
Weight
Approx. 5 g
 Approved Standards
UL478, UL1950, UL508 (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR24825)
Contact form
Coil ratings
Contact ratings
G5V-2
G5V-2-H1
DPDT
3 to 48 VDC
0.6 A, 125 VAC (general use)
0.6 A, 110 VDC (resistive load)
2 A, 30 VDC (resistive load)
0.5 A, 125 VAC (general use)
0.2 A, 110 VDC (resistive load)
1 A, 24 VDC (resistive load)