Crydom SOLID-STATE-RELAY DRTU24A06R DRTU24A06R データシート
製品コード
DRTU24A06R
DataSheet
Solid State Relay Timer
T
C
L
A
T
C
L
H
T
C
L
Y1
B
T
C
L
T
T
T
T
Di
C
L
Y1
T
T
Ac
T=t1+t2+t3
Y1
L
t1
t2
t3
At
C
T=t1+t2+t3
C
L
t1
t2
t3
Y1
Ht
T
C
L
Y1
C
T
C
L
T
T
T
T
A1Y1
D
C
L
Y1
T
T
Bw
C
L
A1Y1
T
on
T
off
T
on
T
off
T
off
L
T
on
C
L
T
off
T
on
T
off
Li
LED Status by Function
Function
Control Voltage
Y1
Timing
Output State
LED Status
Notes
A/At
Delay On Make
Off
On
On
Off
On
On
On
Off
On
On
On
On
Off
On
On
On
Off
On
On
On
On
On
On
Off
On
Off
On
Off
On
On
Open
Open
Closed
Closed
Open
Open
Closed
Open
Open
Open
Open
Closed
Closed
Open
Open
Open
Closed
Closed
Open
Open
Off
On
Timed Out
Off
Off
On
Timed Out
Off
Off
Off
On
Timed Out
Off
Off
On
Timed Out
Off
Off
Off
On
Timed Out
On
Timed Out
Off
On
Off
On
Off
On
Timed Out
Off
Off
On
Off
Off
On
Off
Off
Off
On
On
Off
Off
Off
Off
On
Off
Off
Off
On
Off
On
Off
Off
On
Off
On/Off
Off
On/Off
Off
Off
Long Flashes
On
Off
Short Flashes
Long Flashes
Short Flashes
Off
Short Flashes
On
Long Flashes
Short Flashes
Off
Short Flashes
Long Flashes
On
Off
Short Flashes
Long Flashes
Short Flashes
Long Flashes
Short Flashes
Off
Long Flashes
Off
Long Flashes/Short Flashes
Off
Long Flashes/Short Flashes
Short Flashes
H/Ht
Interval
D/Di
Repeat Cycle
L/Li
Repeat Cycle
B
Single Shot
C
Delay On Break
Ac
Delay On Make /
Delay On Break
Bw
At function is identical to the A function except when Y1 is connected to A1 timing is paused. When Y1 is
removed timing resumes until relay times out. To reset timer remove control power.
Ht function is identical to the H function except when Y1 is connected to A1 timing is paused. When Y1 is
removed timing resumes until relay times out. To reset timer remove control power.
Y1 switch can be momentary or maintained to A1. To
reset timer after relay has timed out Y1 has to be
opened.
Y1 switch to A1 must be momentary for timing to
begin. If during timing Y1 is closed again the time
delay is reset and will begin again once Y1 is
removed. Once timed out timer is reset and ready for
the next cycle.
Y1 to A1 switch can be momentary or maintained. If
maintained until relay has timed out removing it will
start timing again. If momentary and timers has
timed out reapplying Y1 will start timing again.
To start Delay on Make (A) timing connect Y1 to A1
and maintain until LED is on Solid then to start Delay
on Break (c) portion remove Y1 until relay times out.
Removing Y1 During (A) portion or Connecting Y1
during (c) portion will reset time for that portion.
To select between on time (Di) first or off time (D) first Y1 is connected. Default is On time (Di) first, for Off
time (D) first connect Y1. Equal On/Off time.
To select between on time (Li) first or off time (L) first Y1 is connected A1. Default is On time (Li) first, for Off
time (L) first connect Y1 to A1. Time delay is independent of each other.
LED STATUS FUNCTION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
IEC 60068-2-6 : Vibration 0.35mm and 0.75mm Amplitutde over 10-55 Hz
IEC 60068-2-27 : Shock 15G/11ms
IEC 61000-4-2 : Electrostatic Discharge Level 3
IEC 61000-4-4 : Electrically Fast Transients Level 3
IEC 61000-4-5 : Electrical Surges Level 3
E116949
093013
Do not forget to visit us at:
www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.
IND. CONT. EQ.
4WB8