Finder 56.32.9.110.0040 PCB Mount Relay 56.32.9.110.0040 データシート
![Finder](https://files.manualsbrain.com/attachments/2ff21089e5cc4b71108c7c1dd0c66b81ce9f009f/common/fit/150/50/80f54547e28bbe39d4385a567b8f6a2b4fcf8f94d8139f4e47302d525c77/brand_logo.gif)
製品コード
56.32.9.110.0040
4
Technical data
Contact specification
F 56 - Electrical life (AC) v contact current
2 - 4 pole relays
Cycles
DC voltage (V)
DC breajking current (A)
• When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·10
3
can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Note: the release time of the load will be increased.
DC voltage (V)
DC breaking current (A)
Resistive load - cos
ϕ = 1
Inductive load - cos
ϕ = 0.4
H 56 - Maximum DC1 breaking capacity
Changeover version
H 56 - Maximum DC1 breaking capacity
Normally open version
contacts in series
contacts in series
Insulation according to EN 61810-1
2 CO - 4 CO
2 NO
Nominal voltage of supply system
V AC
230/400
230/400
Rated insulation voltage
V AC
250
400
250
400
Pollution degree
3
2
3
2
Insulation between coil and contact set
Type of insulation
Basic
Basic
Overvoltage category
III
III
Rated impulse voltage
kV (1.2/50 µs)
4
4
Dielectric strength
V AC 2,500
2,500
Insulation between adjacent contacts
Type of insulation
Basic
Basic
Overvoltage category
III
III
Rated impulse voltage
kV (1.2/50 µs)
4
4
Dielectric strength
V AC 2,500
2,500
Insulation between open contacts
Type of disconnection
Micro-disconnection
Full-disconnection*
Overvoltage category
—
II
Rated impulse voltage
kV (1.2/50 µs)
—
2.5
Dielectric strength
V AC/(1.2/50 µs)
1,000/1.5
2,000/3
Conducted disturbance immunity
Burst (5...50) ns, 5 kHz, on A1 - A2
Burst (5...50) ns, 5 kHz, on A1 - A2
EN 61000-4-4
level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode)
EN 61000-4-5
level 4 (4 kV)
Other data
Bounce time: NO/NC
Bounce time: NO/NC
ms
1/4 (changeover)
3/— (normally open)
Vibration resistance (10…150 Hz ): NO/NC
g
17/14
Shock resistance NO/NC
g
20/14
Power lost to the environment
without contact current
W
1 (56.32, 56.42)
1.3 (56.34, 56.44)
with rated current
W
3.8 (56.32, 56.42)
6.9 (56.34, 56.44)
Recommended distance between relays mounted on PCB
mm
≥
5
*Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection.
I-2014, www
.finder
net.com
56
SERIE S
56 Series - Miniature power relays 12 A
A