7.4 Deleting User Password
To delete a user password, enter the following combination in the programming mode:
* 50 XX
In this case XX stands for user (01 to 99), which is to be deleted.
7.5 Setting of Timer
You can determine the duration for triggering the relay (cable colours black + yellow) for the
electric door opener yourself. To do this, enter the following combination, while you are in the
programming mode:
* 20 TT
In this case TT stands for 01 to 99 seconds.
If you set it to 00, the relay contact for the door opener stays active until the user password is
entered again.
7.6 Key Pad Lock
When the password is entered incorrectly five times consecutively, the key pad (4) is locked
for 30 seconds.
The automatic key lock (30 seconds) can be activated/deactivated. To do this, enter the
following combination, while you are in the programming mode:
* 51