Merten Insert Dimmer System M, System Area MEG5132-0000 MEG5132-0000 プリント
製品コード
MEG5132-0000
V5131-581-01 02/12
Rotary dimmer insert for ohmic loadMEG5131-0000, MEG5132-0000© Merten 2009V5131-581-0102/12
¼
DANGER
Risk of death from electric shock.
All work on the device should only be carried out
by trained and skilled electricians. Observe the
country-specific regulations.
¼
DANGER
Risk of death from electric shock.
The outputs may carry an electrical current even
when the device is switched off. Always discon-
nect the fuse in the incoming circuit from the sup-
ply before working on connected loads.
With the rotary dimmer insert (hereafter referred to as
"dimmer"), you can use a rotary knob to switch and dim
ohmic loads such as
• Incandescent lamps and
• 230 V halogen lamps.
• Incandescent lamps and
• 230 V halogen lamps.
½
CAUTION
The device can be damaged.
• Always operate the device with the specified
• Always operate the device with the specified
minimum load.
• Protect the circuit with a 10 A fuse if further
loads are to be looped on the X terminal of the
device.
|
The maximum allowed load is reduced due to the
decreased heat dissipation when you do not in-
stall the device into a single standard flush-
mounted mounting box:
* If several factors apply, add the load reductions togeth-
er.
Rotary dimmer insert for ohmic load
Operating instructions
MEG5131-0000, MEG5132-0000
For your safety
Rotary dimmer insert – introduction
Installing the dimmer
Load
re-
duc-
tion
by
Mounted
in cavity
walls *
Several
installed
together in
combination
*
In 1-gang
or 2-gang
surface-
mounted
housing
in 3-
gang
surface-
mount-
ed hous-
ing
25 %
x
x
30 %
x
50 %
x
en
de
Wiring the dimmer for the desired application.
MEG5131-0000 connection:
MEG5131-0000 connection:
MEG5132-0000 connection:
Setting the minimum brightness of the lamps.
|
The connected lamps should glow with a mini-
mum brightness when the dimmer is switched on
and when the rotary switch has been dimmed
down.
Set the minimum brightness before installing the
covers.
1 Switch the dimmer on.
2 Dim the brightness right down using the rotary knob.
3 Set the minimum brightness using the set-screw
2 Dim the brightness right down using the rotary knob.
3 Set the minimum brightness using the set-screw
(MIN).
Installing the dimmer and covers.
L
N
N
X
L
L
N
N
X
L
L
MIN
• You switch the connected lamps on and off by press-
ing the rotary knob A once.
• By turning the rotary knob B, you dim the lamps
brighter or darker.
The connected lamp doesn't switch on.
• Check the fuse, replace if necessary.
• If there is an overload due to the fact that the operating
• Check the fuse, replace if necessary.
• If there is an overload due to the fact that the operating
temperature is too high, it will not be possible to switch
the dimmer back on and it must be replaced.
1 Remove the covers.
2 Prise the fuse holder out using a screwdriver.
3 Remove blown fuse A and replace with replace-
2 Prise the fuse holder out using a screwdriver.
3 Remove blown fuse A and replace with replace-
ment fuse B.
Merten GmbH, Fritz-Kotz-Str. 8, D-51674 Wiehl
www.merten.com
Service Center:
www.merten.com
Service Center:
Technical support / InfoLine:
Operating the dimmer
What should I do if there is a problem?
How to change the fuse
Technical data
Mains voltage:
AC 230 V, 50 Hz
Nominal load:
40 - 400 W
Minimum load:
40 W
Load type:
Ohmic load
Short-circuit protection:
Fuse F6.3AH
Surge protection:
Electronic
Operating temperature:
+5°C to +35°C
Two-way circuit:
MEG5132-0000 only
Merten GmbH
Phone: +49 2261 702-204
Fax:
Fax:
+49 2261 702-136
E-Mail: servicecenter@merten.de
Phone: +49 2261 702-235
Fax:
Fax:
+49 2261 702-680
E-Mail: infoline.merten@schneider-electric.com
25-600 V
A 230 V ~
50 Hz
T2.5H
25-600 V
A 230 V ~
50 Hz
T2.5H
A
B
A
B