Merten Insert Dimmer System M, System Area MEG5170-0300 MEG5170-0300 プリント
製品コード
MEG5170-0300
V5170-581-00 12/11
System M
System Design
– Complete the universal dimmer for CFLs / LED lamps
with:
• corresponding 2-gang rockers in design System M or
System Design.
• frames in design System M or System Design.
¼
DANGER
Risk of death from electric shock.
All work on the device should only be carried out
by trained and skilled electricians. Observe the
country-specific regulations.
¼
DANGER
Risk of death from electric shock.
The outputs may carry an electrical current even
when the device is switched off. Always discon-
nect the fuse in the incoming circuit from the sup-
ply before working on connected loads.
Universal dimmer for CFLs / LED lamps
Operating instructions
Universal dimmer for CFLs / LED
lamps
Art. no. MEG5170-0300
Universal dimmer for CFLs / LED
lamps
Art. no. MEG5170-4000
Necessary accessories
For your safety
en
de
You can use the universal dimmer for CFLs / LED lamps
(referred to below as the device) to switch and dim ohm-
ic, inductive or capacitive loads:
The device automatically recognises the connected
load. The device is overload-proof, short-circuit-proof
and has a soft start function.
The device has two scene buttons for retrieving, chang-
The device has two scene buttons for retrieving, chang-
ing and saving two scenes.
When energy-saving lamps are connected, additional
When energy-saving lamps are connected, additional
possible settings are activated. You can set the dimming
range, switch off the start function and switch the operat-
ing mode (from trailing edge phase control to leading
edge phase control, recommended for Osram).
½
CAUTION
The device can become damaged!
• Always operate the device in compliance with
• Always operate the device in compliance with
the specified technical data.
• Operate the device with a minimum load of
10 VA.
• Connected devices can become damaged if
you connect mixed loads (inductive and capac-
itive) at the same time.
• When energy-saving lamps are used: Only
connect energy-saving lamps from the same
manufacturer.
• The device is designed for sinusoidal mains
voltage.
• When transformers are used: Only connect
dimmable transformers to the dimmer.
• Dimming socket-outlets is prohibited. The risk
of overloading and the risk of unsuitable devic-
es being connected is too high.
• If a terminal is used for looping, the device must
be protected with a 6 A circuit breaker.
Getting to know the universal dimmer
incandescent lamps
(ohmic load)
230 V halogen lamps
(ohmic load)
Low-voltage halogen lamps with
dimmable wound transformer
(inductive load)
Low-voltage halogen lamps with
Low-voltage halogen lamps with
electric transformer
(capacitive load)
Dimmable energy-saving
Dimmable energy-saving
lamps:
• Osram
• Philips
• Govena
• Megaman
• Osram
• Philips
• Govena
• Megaman
Dimmable LED lamps:
• Osram
• Philips
• Ledon
• Toshiba
• Osram
• Philips
• Ledon
• Toshiba
|
Connect at most three dimmers to one cable with
16 A fuse protection!
|
If you do not install the device in a single, standard
flush mounting box, the maximum permissible
load is reduced due to the restricted heat dissipa-
tion:
* If several factors apply, add the load reductions togeth-
er.
Wiring the insert
Installing the device
Installing the device
Load reduced
by
when installed
25 %
in hollow walls *
Several installed together in combi-
Several installed together in combi-
nation *
30 %
in 1-gang or 2-gang surface-mount-
ed housing
50 %
in 3-gang surface-mounted housing
L
L
N
N
OR
|
The following functions are only available when
energy-saving lamps are connected.
Dimming range
In order to be able to dim energy-saving lamps from dif-
ferent manufacturers without faults, the dimming range
has been restricted. However, you can adjust the dim-
ming range to your energy-saving lamp.
Setting the dimming range
|
When setting the dimming range, problems may
occur (see chapter "What should I do if there is a
problem?")
1 Call up setting mode (the lamps are briefly switched
off and on)
2 Set max. brightness value
3 Temporarily save max. brightness value
4 Set min. brightness value
5 Temporarily save min. brightness value
6 Save values permanently and exit setting mode (the
3 Temporarily save max. brightness value
4 Set min. brightness value
5 Temporarily save min. brightness value
6 Save values permanently and exit setting mode (the
lamps are briefly switched off and on)
Start function
Most energy-saving lamps need time to warm up when
switched on. The start function is therefore activated au-
tomatically when an energy-saving lamp is connected.
The energy-saving lamp is operated at maximum bright-
The energy-saving lamp is operated at maximum bright-
ness for approx. 2 s when switched on and then dims au-
tomatically to the desired brightness.
Switching off the start function
This can be switched off for energy-saving lamps which
This can be switched off for energy-saving lamps which
do not require a start function.
Seting the device
> 3 s
> 3 s
> 3 s
2
3
4
5
1 / 6
10x
Operating mode
When connecting energy-saving lamps, "trailing edge
phase control" operating mode is automatically activat-
ed.
Changing operating mode
For certain energy-saving lamps, e.g. Osram, you have
For certain energy-saving lamps, e.g. Osram, you have
to switch to "leading edge phase control" operating
mode.
Switching load on/off
Dimming load
Retrieving light scenes
Standard scenes
All devices are delivered from the factory with preset-
All devices are delivered from the factory with preset-
tings for a light scene.
Changing and saving light scenes
1 Set the brightness value.
2 Save scene: press the S1 or S2 push-button for a
2 Save scene: press the S1 or S2 push-button for a
long time.
Resetting to default settings
Operating the device
S1:
light on (100%)
S2: light
off
Operation
Status feedback
Lamps switch off and
Lamps switch off and
back on twice within
10 s.
6x
< 0,5 s
> 0,5 s
< 0,5 s
> 3 s
1
2
10 s
The device regularly dims down during operation
and cannot be dimmed up.
• Allow the device to cool down and reduce the con-
• Allow the device to cool down and reduce the con-
nected load.
The load cannot be switched back on.
• Allow the device to cool down and reduce the con-
• Allow the device to cool down and reduce the con-
nected load.
• Rectify any possible short circuits.
• Renew defective loads.
LV halogen lamps are not switched on with soft
• Renew defective loads.
LV halogen lamps are not switched on with soft
start.
Electronic transformers are detected as energy-saving
Electronic transformers are detected as energy-saving
lamps.
• Make settings for energy-saving lamps (switch off the
• Make settings for energy-saving lamps (switch off the
start function, increase dimming range).
The load is dimmed to the minimum brightness.
The brightness has exceeded the maximum value for the
The brightness has exceeded the maximum value for the
energy-saving lamp.
• Reduce the maximum brightness value (setting dim-
• Reduce the maximum brightness value (setting dim-
ming range).
The load flickers at min. brightness setting.
The brightness has not reached the minimum value for
The brightness has not reached the minimum value for
the energy-saving lamp.
• Increase the minimum brightness value (setting dim-
• Increase the minimum brightness value (setting dim-
ming range).
The load flickers continuously.
Incorrect operating mode (e.g. for Osram) set.
• Switch operating mode to leading edge phase control.
The load can only be dimmed slightly.
The dimming range is set too low.
• Increase the dimming range.
Incorrect operating mode (e.g. for Osram) set.
• Switch operating mode to leading edge phase control.
The load can only be dimmed slightly.
The dimming range is set too low.
• Increase the dimming range.
Merten GmbH, Fritz-Kotz-Str. 8, D-51674 Wiehl
www.merten.com
Service Center:
www.merten.com
Service Center:
Technical support / InfoLine:
What should I do if there is a problem?
Technical data
Mains voltage:
AC 220/230 V ∼, 50/60 Hz
Switching capacity:
10-200 VA
for energy-saving
lamps and leading
edge phase control:
max. 40 VA
wound, dimmable
transformers:
min. 40 VA
Neutral conductor:
not required
Connecting terminals:
Screw terminals for max. 2x
2.5 mm
2
or 2x 1.5 mm
2
Protection:
16 A circuit breaker
Features:
• Short-circuit-proof
• overload-proof
• soft start
• automatic load detection
• overload-proof
• soft start
• automatic load detection