Description 
 
 
 
1   2  
2  1 
 
 
 
1   PCB holder 
2   Wall fixing 
 
 
 
 
 
 
 

 
 
[Fig. 1] Casing open 
(with PCB) 
[
Fig. 2] Casing without PCB 
 
 
 
Installation 
 
1.  Using the key supplied, unscrew the cover screws and remove 
the cover plate. 
 
2.  Remove the two PCB screws on the left and right of the cylinder. 
 
3.  Pull the cylinder and PCB carefully upwards and out. 
 
4.  Use the back  of the key-switch case  as a  template for marking 
the drill holes (2). Drill the holes for the fixing screws. 
 
5.  Fix the key switch to the wall using the screws supplied. 
 
6.  Replace the PC board. Make sure that the anti-removal tamper 
contact is pressed. 
 
7.  Connect the battery supplied. 
 
8.  Replace the cover and screw it tight with the four special screws.