Mai 06
47
6.3
Automatic Logout and Login
Scheduled logout/login can be activated using the HSComm. Click on the tab “Basic Set-
tings”.
tings”.
6.3.1 Automatic login at restart
The INSYS GPRS 5.0 serial can store the SIM card PIN inter-
nally, which enables it to log into the GSM network after each
restart and reset, without user intervention.
All four globally used frequency ranges 850 MHz, 900 MHz,
1800 MHz and 1900 MHz are supported. At the respective
location, the INSYS GPRS 5.0 serial will automatically operate
with the frequency range provided by the network provider.
nally, which enables it to log into the GSM network after each
restart and reset, without user intervention.
All four globally used frequency ranges 850 MHz, 900 MHz,
1800 MHz and 1900 MHz are supported. At the respective
location, the INSYS GPRS 5.0 serial will automatically operate
with the frequency range provided by the network provider.
Before using the INSYS GPRS 5.0 serial, you should
check the certification requirements in the country of
deployment.
deployment.
AT**PIN=<pin>
Note: As default, the INSYS GPRS 5.0 serial will login to the
strongest available GSM network. If required, a pre-
ferred network can be pre-selected with the command
AT**PROVIDER, if necessary.
ferred network can be pre-selected with the command
AT**PROVIDER, if necessary.
AT**PROVIDER=
<mode>[,<format>[,
<oper>]]
<mode>[,<format>[,
<oper>]]
6.3.2 Scheduled logout/login
For function support even after infrastructure changes and
network software updates by the network providers, the IN-
SYS GPRS 5.0 serial can be logged out of the GSM network via
a timer. The timer can be set by the hour up to a maximum of
99 hours and starts when the device is switched on. One
minute after the logout, the INSYS GPRS 5.0 serial will auto-
matically log back in. The timer restarts.
network software updates by the network providers, the IN-
SYS GPRS 5.0 serial can be logged out of the GSM network via
a timer. The timer can be set by the hour up to a maximum of
99 hours and starts when the device is switched on. One
minute after the logout, the INSYS GPRS 5.0 serial will auto-
matically log back in. The timer restarts.
If a TCP transparent or a data connection (CSD or GPRS) is
established at the time of the logout, the logout will wait
until the connection is terminated.
In our example, the INSYS GPRS 5.0 serial will be logged out
and back in every 3 hours.
established at the time of the logout, the logout will wait
until the connection is terminated.
In our example, the INSYS GPRS 5.0 serial will be logged out
and back in every 3 hours.
Alternatively, the scheduled logout/login can be set,
changed or deleted using the terminal program.
changed or deleted using the terminal program.
AT**LOGOUT=<n>
E.g.: 3 hours
AT**LOGOUT=3