12-6
Media Converters  
>
TCF-142 Series
w w w. m o x a . c o m
i n f o @ m o x a . c o m
Serial Expansion and Extension Solutions
12
Dimensions
TCF-142-M/S-ST
DIP Switch Settings
Serial Connection
SW1 SW2
RS-232
ON
OFF
RS-422
OFF
OFF
RS-485-4w
OFF
OFF
RS-485-2w
OFF
ON
Built-in 120-ohm Terminator
SW3
Enable
ON
Disable
OFF
Fiber Mode
SW4
Ring mode
ON
Point-to-Point mode
OFF
RS-232/422/485 Side
Connector: Terminal Block
RS-232 Signals: Tx, Rx, GND
RS-422 Signals: TxD+, TxD-, RxD+, RxD-, GND
RS-485-4w Signals: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w Signals: Data+, Data-, GND
Baudrate: 300 bps to 921.6 Kbps
ESD Protection: 15 KV for all signals
Optical Fiber Side
Fiber Connector: SC or ST
Cable Requirements:
Single-mode: 8.3/125, 8.7/125, 9/125, or 10/125 µm
Multi-mode: 50/125, 62.5/125, or 100/140 µm
Transmission Distance:
Single-mode: 40 km
Multi-mode: 5 km
Wavelength:
Single-mode: 1310 nm
Multi-mode: 820 nm
Tx Output:
Single-mode: > -5 dBm
Multi-mode: > -5 dBm
Rx Sensitivity:
Single-mode: -25 dBm
Multi-mode: -20 dBm
Point-to-Point Transmission: Half-duplex or full-duplex
Ring Transmission: Half-duplex
Physical Characteristics
Case: Aluminum (1 mm)
Dimensions:
Without ears: 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in)
With ears: 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in)
Environmental Limits
Operating Temperature:
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 85°C (-40 to 185°F)
Power Requirements
Input Voltage: 12 to 48 VDC
Power Consumption: 140 mA @ 12 V
Power Line Protection:
2 KV Burst (EFT), EN61000-4-4
2 KV Surge, EN61000-4-5
Voltage Reversal Protection: Protects against V+/V- reversal
Over Current Protection: 1.1 A (protects against two signals shorted 
together)
Regulatory Approvals
UL/CUL: UL60950-1
TÜV: EN60950-1
FCC: Part 15 Subclass B
EMI: EN55022 1998, Class B
EMS:
EN61000-4-2 (ESD), Criteria A, Level 2
EN61000-4-3 (RS), Criteria A, Level 2
EN61000-4-4 (EFT), Criteria A, Level 2
EN61000-4-5 (Surge), Criteria A, Level 3
EN61000-4-6 (CS), Criteria A, Level 2
EN61000-4-11(DIPS), Criteria A, Level 2
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Specifi cations
100.4 mm (3.95 in)
22.0 mm
(0.87 in)
21.3 mm
(0.8 in)
42.3 mm (1.67 in)
67 mm (2.64 in)
78 mm (3.07 in)
12.5 mm
(0.49 in)
25 mm (0.98 in)
O 6 mm
(0.24 in)
O 4 mm
(0.16 in)
O 7 mm
(0.28 in)
90.2 mm
(3.55 in)
67 mm
(2.64 in)
22.0 mm
(0.87 in)
ON