Signals of Power Connector  
 
PIN 
Signal 
Direction 
Limits 
Description 
VCC 
Input 
5 – 36V 
Positive power input, DC 
ADC_IN or 
 not connected 
Input 
0 – 36V 
- Analogue Input in GT864 PY  
- No connection in GT864 Quad version 
HR_IN 
Input 
5 – 36V 
Active high control line used to switch off  
V
IH 
> 5V, V
IL 
< 0.5V 
Power off: 1s < t < 2s 
TO_IN 
Input 
5 – 36V 
Positive edge triggered signal; used to 
switch on the 
modem 
V
IH 
> 5V, V
IL 
< 0.5V 
Power on: t > 1s  
DIG_OUT / or 
not connected 
Output 
5 –  VCC 
max. 36V 
- Digital Output in GT864 PY 
- No connection in GT864 Quad version 
GND 
Input 
Negative power (ground) input and return 
path for TO_IN and HR_IN 
 
2.1.1  Analogue Input - GT864 PY Variant only 
 
The following command has to be used to initialise and to read the status of the 
analogue input: 
 
AT#ADC=1,2,0 or AT#ADC=1,2 
 
Response: 
 
#ADC: <digital value> 
e.g. 
#ADC: 119 
 
ADC_ IN ≈ 0,026V x digital value 
 
Examples: 
 
ADC_IN [V] 
5V 
12V 
24V 
32V 
digital value 
192 
461 
923 
1230