Conrad Energy D battery (rechargeable) NiMH MONO 8000 MAH 8000 mAh 1.2 V 2 pc(s) 251057 データシート

製品コード
251057
ページ / 4
 
1
CHARACTERISTICS
   
Unless special stated, tests should be carried out within one month of delivery. 
Ambient conditions: 
Ambient Temperature: 20±5℃   
Relative Humidity:   65±20%RH 
Notes: 1)Standard charge/discharge condition 
Charge:    800 mA(0.1C)×16hrs 
Discharge:  1600 mA(0.2C) to 1.0V   
2)Except special explaining, the battery shall not leakage and PVC shall not breakage during the test. 
 
Test  Items 
Test   Conditions 
Requirements 
Remark 
Capacity 
Standard Charge and Discharge 
Discharge Capacity: 
  ≥8000 mAh 
up to three cycles 
are allowed 
Internal 
Impedance(Ri) 
At 1kHz internal impedance between the 
battery terminals shall be measured 
within 1 hour after standard charge 
≤30 mΩ 
 
Open-circuit  
Voltage (OCV) 
Voltage between the battery terminals 
shall be measured within 1 hour after 
standard charge   
≥1.25 V/cell 
 
High-rate   
discharge  
After standard charge, rest for 1 hour 
before discharge to 1.0V at 4000 mA 
current. 
≥108minutes 
up to three cycles 
are allowed 
IEC cycle life 
IEC61951-2/2003/7.4.1.1 See Remark 1 
≥500 cycles 
 
Standard charged , stored for 180 days 
below 20℃,then standard discharge to 
1.0V 
Discharge Capacity: 
≥85% original capacity ★   
Self- discharge 
Standard charged , stored for 360 days 
below 20℃,then standard discharge to 
1.0V 
Discharge Capacity: 
≥80% original capacity ★ 
 
Over-charge 
Charge at 800 mA (0.1 C) for 1 year.   
No leakage, nor disrupt, nor 
burst. 
 
Over- discharge 
After standard discharge , be conducted 
with constant load resistor 1Ω for 3 
days  
Then standard charge and discharge 
Discharge Capacity: 
  ≥80%original capacity 
 
Vibration 
resistance 
Standard charge. Then leave for 24 
hours, check cell before/after vibration. 
Ampliture:1.5mm 
Vibration:3000CPM 
 
Change of voltage: 
ΔV<0.02V/ cell 
Change of internal 
impedance 
ΔR<5mΩ/ cell 
Any direction for 60 
minutes