Microchip Technology MCU PIC10F322T-I/OT SOT-23-6 MCP PIC10F322T-I/OT データシート
![Microchip Technology](https://files.manualsbrain.com/attachments/cf42c3c895ef469f06d2e47e97fd98d738fcf5cf/common/fit/150/50/7340124dc8aa983aaf764094e2f06faab86f306c03111c5817f7e4e53fb2/brand_logo.gif)
製品コード
PIC10F322T-I/OT
PIC10(L)F320/322
DS41585A-page 176
Preliminary
2011 Microchip Technology Inc.
24.4
DC Characteristics: PIC10(L)F320/322-I/E
DC CHARACTERISTICS
Standard Operating Conditions (unless otherwise stated)
Operating temperature -40°C
Operating temperature -40°C
T
A
+85°C for industrial
-40°C
T
A
+125°C for extended
Param
No.
Sym.
Characteristic
Min.
Typ†
Max.
Units
Conditions
V
IL
Input Low Voltage
I/O PORT:
I/O PORT:
D032
with TTL buffer
—
—
0.8
V
4.5V
V
DD
5.5V
D032A
—
—
0.15 V
DD
V
1.8V
V
DD
4.5V
D033
with Schmitt Trigger buffer
—
—
0.2 V
DD
V
2.0V
V
DD
5.5V
D034
MCLR
—
—
0.2 V
DD
V
V
IH
Input High Voltage
I/O ports:
I/O ports:
D040
with TTL buffer
2.0
—
—
V
4.5V
V
DD
5.5V
D040A
0.25 V
DD
+
0.8
—
—
V
1.8V
V
DD
4.5V
D041
with Schmitt Trigger buffer
0.8 V
DD
—
—
V
2.0V
V
DD
5.5V
D042
MCLR
0.8 V
DD
—
—
V
I
IL
Input Leakage Current
(2)
D060
I/O ports
—
± 5
± 5
± 125
± 1000
nA
nA
V
SS
V
PIN
V
DD
, Pin at
high-impedance @ 85°C
125°C
125°C
D061
MCLR
—
± 50
± 200
nA
V
SS
V
PIN
V
DD
@ 85°C
I
PUR
Weak Pull-up Current
D070*
25
25
25
100
140
140
200
300
300
A
V
DD
= 3.3V, V
PIN
= V
SS
V
DD
= 5.0V, V
PIN
= V
SS
V
OL
Output Low Voltage
D080
I/O ports
—
—
0.6
V
I
OL
= 8mA, V
DD
= 5V
I
OL
= 6mA, V
DD
= 3.3V
I
OL
= 1.8mA, V
DD
= 1.8V
V
OH
Output High Voltage
D090
I/O ports
V
DD
- 0.7
—
—
V
I
OH
= 3.5mA, V
DD
= 5V
I
OH
= 3mA, V
DD
= 3.3V
I
OH
= 1mA, V
DD
= 1.8V
*
These parameters are characterized but not tested.
†
Data in “Typ” column is at 3.0V, 25°C unless otherwise stated. These parameters are for design guidance only and are
not tested.
not tested.
Note 1:
Negative current is defined as current sourced by the pin.
2:
The leakage current on the MCLR pin is strongly dependent on the applied voltage level. The specified levels represent
normal operating conditions. Higher leakage current may be measured at different input voltages.
normal operating conditions. Higher leakage current may be measured at different input voltages.