Microchip Technology XC8 Standard Compiler (Workstation) SW006021-1 SW006021-1 ユーザーズマニュアル

製品コード
SW006021-1
ページ / 518
XC8 Command-line Driver
 2012 Microchip Technology Inc.
DS52053B-page 101
4.8.22
--CODEOFFSET: Offset Program Code to Address
In some circumstances, such as bootloaders, it is necessary to shift the program image 
to an alternative address. This option is used to specify a base address for the program 
code image and to reserve memory from address 0 to that specified in the option.
When using this option, all code psects (including Reset and interrupt vectors and con-
stant data) will be adjusted to the address specified. The address is assumed to be a 
hexadecimal constant. A leading 0x, or a trailing h hexadecimal specifier can be used, 
but is not necessary.
This option differs from the --ROM option in that it will move the code associated with 
the Reset and interrupt vectors which cannot be done using the --ROM option, see 
Section 4.8.49 “--ROM: Adjust ROM Ranges”.
For example, if the option --CODEOFFSET=600 is specified, the Reset vector will be 
moved from address 0 to address 0x600; the interrupt vector will be moved from 
address 4 to 0x604, in the case of mid-range PIC devices, or to the addresses 0x608 
and 0x618 for PIC18 devices. No code will be placed between address 0 and 0x600.
4.8.23
--DEBUGGER: Select Debugger Type
This option is intended for use for compatibility with development tools which can act 
as a debugger. xc8 supports several debuggers and using this option will configure the 
compiler to conform to the requirements of that selected. The possible selections for 
this option are defined in Table 4-8.
For example:
xc8
 --CHIP=16F877AA --DEBUGGER=icd2 main.c
Choosing the correct debugger is important as they can use memory resources that 
could otherwise be used by the project if this option is omitted. Such a conflict would 
lead to runtime failure.
If the debugging features of the development tool are not to be used (for example, if the 
MPLAB ICD 3 is only being used as a programmer), then the debugger option can be 
set to none, because memory resources are not being used by the tool.
SeSection 4.9 “MPLAB IDE V8 Universal Toolsuite Equivalents” for use of this 
option in MPLAB IDE. MPLAB X IDE should automatically apply this option for debug 
builds only once you have indicated the hardware tool in the Project Preferences.
TABLE 4-8:
SELECTABLE DEBUGGERS
Suboption
 Debugger selected
none
No debugger (default)
icd2
MPLAB
®
 ICD 2
icd3
MPLAB ICD 3
pickit2
PICkit™ 2
pickit3
PICkit 3
realice
MPLAB REAL ICE™ in-circuit emulator