Test Procedure
www.ti.com
7.6
Restoring the UCD9224 EVM’s Original Configuration
The file
can be found on the TI website and is provided to
allow the user to return the EVM to its originally configured state. Simply open the Fusion GUI while the
powered EVM is connected to the computer with the USB Interface Adapter. At the default Configuration
Screen select File
Import Project from the dropdown menu at the top of the window and the Select
Project File window will open. Click the Select File button and navigate to the location of and highlight
the HPA464_EVM_Default_Configuration.xml file and click the Open button. Click the Next > button
and the Select Project Items to Import window will open, set the check boxes as shown in
and
click the Next > button. In the Review Parameters to Import window, click the Select All button and then
click the Write Checked button. The Fusion GUI will download the default configuration settings (it may
generate two warnings about NACK of SYNC_OFFSET command, this is OK, the controller NACKs this
command if the value is already zero). When the download is complete, click the Next > button then the
OK button to complete the project file import. The Fusion GUI will perform a device reset after which the
UCD9224EVM-464 should be restored to its original configuration settings.