Texas Instruments BQ2003 Evaluation Module for NiCd/NiMH, switchmode, up to 3A DV2003S1 DV2003S1 データシート

製品コード
DV2003S1
ページ / 5
Number of Cells (JP4): A resistor-divider network is
provided to select 2 to 16 cells (the resulting resistor
value equals N – 1 cells). RB1 is a 200K
Ω resistor, and
RB2 (R16–R22) is jumper-selected.
Temperature Disable: Connecting a 10K
Ω resistor be-
tween THERM and BAT– disables temperature control.
Setup Procedure
1.
Configure DVEN, TM1, TM2, and number-of-cells
(NOC) jumpers.
2.
Connect the provided thermistor or a 10K
Ω resistor
between THERM and BAT-.
Note: RT1 and RT2 match the thermistor provided
and must be changed if a different thermistor type
is used (see Appendix A in the application note,
“Using the bq2003 to Control Fast Charge”).
3.
If using the discharge-before-charge option, connect
a current-limiting discharge load between BAT+
and DSCHG.
4.
If using the INHIBIT function, connect a switch
across JP5 (IN to +V) or connect IN to the control-
ling signal source (3–5V).
5.
Attach the battery pack to BAT+ and BAT-. For
temperature control, the thermistor must contact
the cwlls.
6.
Attach DC current source to DC+ (+) and GND (-)
connections in JP6.
3
DV2003S1
Symbol
Description
Minimum
Typical
Maximum
Unit
Notes
I
DC+
Maximum input current
-
-
2.4
A
V
DC
Maximum input voltage
2.0 + V
BAT+
or 15
-
18 + V
BAT+
or 35
V
Note 1
V
BAT+
BAT+ input voltage
-
-
30
V
V
THERM
THERM input signal
0
-
5
V
I
DSCHG
Discharge load current
-
-
2
A
Note:
1.
The V
DC+
limits consider the 5.1V Zener diode at D9. The voltage at D9 is application-specific and
limits the V
GS
of Q1 to a safe enhancement value during Q1 conduction. See Table 1 for recommended
D9 selections per V
DC+
.
Recommended DC Operating Conditions
Closed Jumper
Number of Cells
R22
14
R21
12
R20
10
R19
8
R18
6
R17
5
R16
4