Cypress Semiconductor CY3280-MBR3 ユーザーズマニュアル

ページ / 90
CY3280-MBR3 Evaluation Kit User Guide, Doc. #: 001-89905 Rev. *B
74
6.
Advanced Topics
6.1
Using PSoC 5LP as USB-I
2
C Bridge
The PSoC 5LP on the CY3280-MBR3 EVK serves as a USB-I
2
C bridge, which can be used to com-
municate with USB-I
2
C software such as Bridge Control Panel. Bridge Control Panel (BCP) is
installed along with PSoC Programmer during kit installation. BCP works with I
2
C, SPI, and RX8
bridges, which communicate with slave devices. This application currently supports CY3240,
MiniProg3, FirstTouch, FirstTouchRF, True-TouchBridge, DVKProg1, and KitProg bridges.
The following steps describe how to use the USB-I
2
C bridge, which can communicate between BCP
and CY8CMBR3116 device.
1. Open BCP from Start > All Programs > Cypress > Bridge Control Panel <version number>.
2. Connect the CY3280-MBR3 EVK to your PC via a USB port using the USB cable.
3. Ensure that the I
2
C selection jumpers J13 and J14 are shorted between pins 1 and 2 to enable 
I
2
C communication between PSoC 5LP and the MBR3 device. Connect jumper J15 in setting C, 
as shown in 
4. Select the KitProg in the BCP to use the USB-I
2
C functionality. On successful connection, the 
‘Connected’ and ‘Powered’ tabs turn green, as shown in 
.
Figure 6-1.  KitProg USB-I
2
C Connected in Bridge Control Panel