Texas Instruments Evaluation Module for TPS51217 20A Synchronous Step Down Controller with DCAP™ Mode TPS51217EVM-533 TPS51217EVM-533 データシート

製品コード
TPS51217EVM-533
ページ / 19
Test Procedure
www.ti.com
5
Test Procedure
5.1
Line/Load Regulation and Efficiency Measurement Procedure
1. Ensure that the load is set to constant resistance mode and to sink 0 Adc.
2. Ensure that the SW1 switch on the EVM is at OFF position before VIN and V5IN are applied.
3. Increase VIN from 0 V to 8 V, using V1 to measure input voltage.
4. Increase V5IN from 0 V to 5, using V2 to measure input voltage.
5. Turn the SW1 switch to the ON position to enable the controller.
6. Input 0 V or 3.3 V (DC) to VID0 and VID1 to select V
OUT
among 0.9 V, 1.0 V, 1.1 V and 1.2 V.
7. Vary load from between 0 Adc to 20 Adc, V
OUT
should remain in load regulation.
8. Vary VIN from between 8 V and 20 V, V
OUT
should remain in line regulation.
9. Decrease the load to 0 A.
10. Input 0 V to VID0 and VID1.
11. Turn the SW1 switch to the OFF position to disable the controller.
12. Decrease V5IN to 0 V.
13. Decrease VIN to 0 V.
5.2
Dynamic Output Voltage Transition Measurement Procedure
1. Follow steps 1 to 5 of Line/Load Regulation and Efficiency Measurement Procedure.
2. Ensure pulse configuration is Return-to-Zero (RZ) with 50% duty ratio.
3. Run the pulse generator. V
OUT
steps down from 1.2 V to 0.9 V as shown in
.
4. Stop the pulse generator. Change the configuration as inverted.
5. Run the pulse generator again. V
OUT
steps up from 0.9 V to 1.2 V as shown in
6. Stop the pulse generator.
7. Follow steps 11 to 13 of Line/Load Regulation and Efficiency Measurement Procedure.
5.3
Equipment Shutdown
1. Shut down load.
2. Shut down pulse generator.
3. Shut down V5IN.
4. Shut down VIN.
5. Shut down FAN.
8
Using the TPS51217EVM-533, High-Performance, Single-Synchronous
SLUU420 – MAY 2010
Step-Down Controller for Notebook Power Supply
Copyright © 2010, Texas Instruments Incorporated