Texas Instruments Evaluation Module for TPS3808G01 TPS3808G01DBVEVM TPS3808G01DBVEVM データシート

製品コード
TPS3808G01DBVEVM
ページ / 11
Setup
www.ti.com
2
Setup
This section describes the jumpers and connectors on the EVM as well as how to properly connect, set
up, and use the TPS3808G01EVM.
2.1
Input / Output Connector Descriptions
J1: RST
This connector is the RST output. Connect this output to a multimeter, oscilloscope, or external circuit
to verify that RST goes low when MONITOR VOLTAGE goes below its threshold.
J2: MR
This connector is the manual reset input of the TPS3808G01. Pulling this pin low causes the device to
signal a reset. For convenience, pull this pin low by placing a short across the connector.
J3: MONITOR VOLTAGE
This connector is the voltage to be monitored. Connect J3 to a power supply or other voltage source.
RST should transition low when this voltage drops below its threshold.
J4: VDD
This connector is the power-supply connection for the TPS3808G01. It can be between 1.7 V and 6.5
V.
J5: GND
This connector is the return connection for the input power supply. It is electrically connected to J6.
J6: GND
This connector is the return connection for the power supply to be monitored. It is electrically
connected to J5.
JP2: RST Pull-Up
Connecting a short across JP2 connects a 10-k
Ω
pull-up resistor to the RST output.
JP3: Reset Timer
The setting of this jumper configures the reset delay of the device as described in
Table 1. Reset Timer Settings
Setting
Description
Open
No connection to CT;
reset delay set to 20 ms
Short connected
CT connected to a timer capacitor;
across pins 1 and 2
reset delay set to 125 ms
Short connected
CT connected to a pull-up resistor;
across pins 2 and 3
reset delay set to 300 ms
JP5: Fixed Rail
Short this jumper for use of a fixed-voltage TPS3808Gxx device.
JP4: Adjustable Rail
Short this jumper for use of the adjustable-voltage TPS3808G01.
2
TPS3808G01EVM
SBVU015 – April 2010
Copyright © 2010, Texas Instruments Incorporated