Test Summary
2.1
I/O and Jumper Connections
2.2
Test Procedure
Test Summary
Table 1. Performance Specification Summary
Specification
Test Conditions
Min
Typ
Max
Unit
V
I(DC)
Input dc voltage
V
REG
+0.5
5.0
5.4
(1)
V
I
O(CHG)
Battery charge current
See
(1)
0.7
1
A
Power dissipation
(V
(DC+)
– V
(BAT+)
)
×
I
(CHG)
1.5
W
(1)
This input voltage maximum is a function of the maximum allowable power dissipation on the IC. The current level is
programmed for 0.7 A. If the programmed charge is changed, then the maximum input voltage must be adjusted. P
maxIC
= 1.5
Watt = I
CHG
(V
DC+
– V
BAT+
).
This chapter describes the test setups used and the tests performed in evaluating the EVM.
Setup: The bq24018 EVM board requires a single-cell Li-Ion or Li-Pol battery pack and a 5-VDC, 1-A
power source to provide input power. The test setup connections and jumper setting selections are
configured for a stand-alone evaluation but can be changed to interface with external hardware, such as a
microcontroller.
Jack
Connect To:
J1-DC+
Power supply positive, preset to 5.0VDC, 1-A current limit
J1-DC–
Power supply ground
J2-BAT+
Positive battery pack terminal
J2-BAT–
Negative battery pack terminal
J2–TTE
NC required — pulled down with 10 k
Ω
resistor on the EVM
J2-BAT–
NC
J3-STAT1
External hardware if J4-EXT is jumpered (not jumpered from factory)
J3-STAT2
External hardware if J5-EXT is jumpered (not jumpered from factory)
J3-DC-
Return for J3 signals
J3–CE
NC required — pulled down with 10-k
Ω
resistor on the EVM
J4 (Jumper)
STAT1 indication location — LED (EVM) | EXT
J5 (Jumper)
STAT2 indication location — LED (EVM) | EXT
Set up the evaluation board as described above, by making the necessary I/O connections and jumper
selections. Before test and evaluation, it is important to verify that the maximum power dissipation
on the IC is not exceeded: P
(MAX)
= 1.5 watts.
1. Turn on the power supply, which was preset to 5.0 VDC and 1 A for the current-limit setting.
2. The bq24018 enters preconditioning mode if the battery is below the V(LOWV) threshold. In this mode,
the bq24018 precharges the battery with a low current (typically I
O(CHG)
/10 = 0.7A/10 = 70 mA) until the
battery voltage reaches the V
(LOWV)
threshold or until the precharge timer expires. If the timer expires,
then the charge current is terminated, the bq24018 enters fault mode, and both LEDs turn off. Toggling
input power or battery replacement resets fault mode.
3. Once the battery voltage is above the V
(LOWV)
threshold, the battery enters fast-charge mode. This
EVM is programmed for 0.7 A of fast-charging current.
4. Once the battery reaches voltage regulation (4.36 V), the current tapers down as the battery reaches
its full capacity.
5. The battery remains at the fast-charge mode until the fast-charge timer expires, the charge taper time
expires, or the charge termination threshold is reached.
6. If the battery discharges to the recharge threshold, the charger starts fast charging.
2
bq24018 (bqTINY™)
SLUU279 – August 2007