Setup of the EVM
2-4
2.3
Setup of the EVM
For proper operation of the EVM, follow these steps:
1) Connect a signal source (or a battery pack) with the appropriate voltage
between the V
IN
 and GND:
REG710–25, 27, 3, 33:
V
IN
 >= 1.8 V
REG710–5:
V
IN
>= 2.7 V
2) Connect a load to the output between V
OUT
 and GND.
REG710–25, 27, 3, 33:
Iload <= 10 mA with V
IN
 >= 1.8 V
REG710–5:
Iload <= 10 mA with V
IN
  >= 2.7 V
REG710–25, 27:
Iload <= 30 mA with V
IN 
>= 2.0 V
REG710–3, 33:
Iload <= 30 mA with V
IN
 >= 2.2 V
REG710–5:
Iload <= 30 mA with V
IN
 >= 3.0 V
3) Connect Venable to Vin to enable the device or to GND to disable the
device. An optional pullup resistor can be placed on the board to ensure
that the device starts immediately.