Texas Instruments TAS5631PHD Evaluation Module TAS5631PHD2EVM TAS5631PHD2EVM データシート
![Texas Instruments](https://files.manualsbrain.com/attachments/b46f99d826b2b0e0e5f558c5fb6483942eb9216b/common/fit/150/50/c15ea36eb1fb1cce99a3b94668675bfc78ce832d8d727d9a7bb51a125510/brand_logo.gif)
製品コード
TAS5631PHD2EVM
-50
50
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
mV
-20
50
-10
0
10
20
30
40
ms
TAS5631PHD2EVM Performance
www.ti.com
4.17 Pop/Click (PBTL)
No input signal applied. The measurement results are presented in time domain. Test with automute
disabled – Register x04h set to x60h. No input signal applied. Load 2
disabled – Register x04h set to x60h. No input signal applied. Load 2
Ω
.
Figure 21. Pop/Click (PBTL)
4.18 Output Stage Efficiency
Efficiency is tested with 2 channels loaded 4
Ω
. The heat sink has been ventilated with a fan during the
test.
20
TAS5631PHD2EVM
SLOU275A – December 2009 – Revised May 2010
Copyright © 2009–2010, Texas Instruments Incorporated