1.2
WHAT THE ENERGY MONITORING PICtail™ PLUS DAUGHTER BOARD 
USER’S GUIDE KIT INCLUDES
The Energy Monitoring PICtail™ Plus Daughter Board Kit includes:
• Energy Monitoring PICtail™ Plus Daughter Board (102-00330)
• Important Information Sheet
1.3
GETTING STARTED
The Energy Monitoring PICtail™ Plus Daughter Board uses a 2A load for calibration 
current, and a maximum current (I
MAX
) of 15A.
All connections described in this section are dependent on the choice of the current 
sensing element. A secondary external transformer may be required in higher current 
meter designs.
To test a calibrated meter, the following connections apply for a two-wire connection.
1.3.1
Step 1: Wiring connections
J5 and J6 are the line and load connections of the meter.
1.3.2
Step 2: Connect the board to a PC running the energy meter 
software
The meter will turn on when the line connection has 110V–240V connected. The PC 
software will show the total energy accumulated.