Moxa OnCell G2150I Industrial Quad Band Modem ONCELL G2150I ユーザーズマニュアル

製品コード
ONCELL G2150I
ページ / 4
Total Solutions for Industrial Device Networking
w w w. m o x a . c o m                   e - m a i l :   i n f o @ m o x a . c o m
6-3
 Wireless & Cellular
6
CSD (Circuit Switched Data) is the original form of data transmission 
developed for GSM systems. With a single radio time slot, CSD can 
transmit data at 9.6 to 14.4 Kbit/sec to both the GSM network and 
the PSTN switching subsystem over a direct call. Most of the time, 
transmission is initiated by standard AT commands. Since CSD 
provides direct modem access to remote devices, system extensions 
can be used without requiring the installation of cables and data lines. 
CSD overcomes the limitations of hard wiring and inaccessible terrain 
for easier, more flexible data collection and monitoring.
CSD Data Connection
The OnCell G2150I are industrial quad-band GSM/GPRS modems that 
transmit data and short messages (SMS) over GSM/GPRS mobile 
networks. They can be used to improve the efficiency of maintenance 
and communication, independent of operating skill. The OnCell G2150I 
are also designed to be mounted on a DIN-rail or on the wall. It has 
a 12 to 48V DC power input, allowing different types of field power 
sources to be attached. The serial ports are also protected by 15 KV 
ESD line protection, so the system is safe from electrical discharge. 
Separate RS-232 and RS-422/485 interfaces are built into the OnCell 
G2150I GSM/GPRS modem, each with 2.5 KV RMS isolation for one 
minute. The two serial interfaces on OnCell G2150I also make it ideal 
for attaching all kinds of devices, such as stand-alone controllers, PC 
COM ports, or multi-dropped electric meters.
OnCell G2150I Introduction
GPRS is packet-switched, which means that multiple users share the 
same transmission channel. It transmits only when there is outgoing 
data. At any moment, the available bandwidth can be dedicated 
immediately for users that are sending or receiving data. In general, 
a GPRS network can be viewed as a special IP network that offers 
IP connectivity to IP terminals. Devices such as PCs, embedded 
computers, and PPP-enabled PLCs can be easily connected to the IP 
network and the Internet.
+1-626-0001
Meter
+1-626-0002
+1-626-0003
Dial-up polling topology
Meter
Meter
Central Station
GPRS
IP Network
PPP Enabled
PC-Controller
GPRS IP Connectivity
The OnCell G2150I provides several LED indicators for basic status 
information. At a glance, users can see the signal strength and the 
Signal LED Indicators
Type
SIGNAL
PWR
GSM
GPRS
DATA
Color
Green
Green
Amber
Amber
Green
Description
Signal level (> L2 for data connection)
Power activated
GSM CSD connection established
GPRS connection established
Serial Tx/Rx
=
SIGNAL
GSM
GPRS
PWR
DATA
Numbers of 
Signal LEDs
Type of signal that can be transmitted
None
No signal, or SIM card is not installed properly, or PIN is 
not entered
1LED
Weak or insufficient (SMS only)
2LEDs
Average (good for GSM CSD and GPRS connections)
3LEDs
Exceptional (good for GSM CSD and GPRS connections)
RS-232
TxD
RxD
RTS
CTS
DTR
DSR
8 Channel
2.5KV Isolation
Remote Cabinet
Remote Cabinet
RTU
PLC
RS-422/485
TXD+
TXD-
RXD-
RXD+
4 Channel
2.5KV Isolation
RI
DCD
G2150I
G2150I
current mode of communication, such as CSD data or GPRS.