Freescale Semiconductor Enhanced serial module TWR-SER2 TWR-SER2 TWR-SER2 ユーザーズマニュアル

製品コード
TWR-SER2
ページ / 17
 
 
 
 
 
TWR-SER2 User’s Manual 
Page 7 of 17 
 
  Device Mode – TWR-SER2 will be connected to a host, such as a host PC. 
o  J24 should be shunted, if it is desired that the entire Tower system be powered via this 
connection. 
 
3.4 Low/Full-Speed Host USB 
The TWR-SER2 features a Host Type-A USB receptacle.  The USB differential signals are connected 
directly to the Tower Elevator USB Signals and will be connected to a compatible Tower System 
MCU/MPU module’s USB Host controller.  In addition to the differential data pair, the MCU should 
provide the VBUS_EN signal and respond to the VBUS_OC signals.  J16 and J21 should be shunted to 
connect VBUS enable/over-current control to the MCU signals. 
3.5 Serial Communications Interface 
The TWR-SER2 is capable of providing up to four additional SCI’s.  The number of accessible SCI’s on 
the TWR-SER2 will depend on the capabilities and Tower Elevator signals connections of the 
MCU/MPU Module. 
3.5.1 RS-232/485 Interface 
UART1 (RXD/TXD) is connected to both an RS-232 transceiver and an RS-485 transceiver, selectable 
by a series of selection jumpers (J1, J2, & J13).  The RS-232 and RS-485 transceivers are terminated 
at a common DB9 connector (J11).  This SCI does not feature any type of flow control capabilities. 
Additional configurations related to the RS485 interface can be made using the MULTI_SEL jumper 
(J2).   Refer to the following tables for jumper setting details. 
 
Jumper 
Pin 
Description 
J1 
2-3 
RXD_SEL 
– Specifies the SCI RX signal is routed to the RS232 Transceiver 
J2 
2-3 
TXD_SEL 
– Specifies the SCI TX signal is routed to the RS232 Transceiver 
J13 
1-2 
SER_SEL 
– Disables communication to and from the RS485 Transceiver 
 
Jumper 
Pin 
Description 
J1 
1-2 
RXD_SEL 
– Specifies the SCI RX signal is routed to the RS485 Transceiver 
J2 
1-2 
TXD_SEL 
– Specifies the SCI TX signal is routed to the RS485 Transceiver 
J13 
2-3 
SER_SEL 
– Disables communication to and from the RS232 Transceiver 
 
MULT
I_S
E
L
 
(J2
) 
Pin 
Description 
1-2 
Connects RS485 Receive EN and Driver EN 
3-4 
Connects RS485 RX+ to TX+; Loopback 
5-6 
Connects RS485 RX- to TX-; Loopback 
7-8 
NC 
9-10 
Connects 5V supply to DB9 pin 6