Voltcraft CO-100 Room Air Meter CO-100 データシート

製品コード
CO-100
ページ / 88
32
8. START-UP
• To take the CO
2
 meter into operation, connect the round plug of the included mains
adapter to the low-voltage socket at the side of the CO
2
 meter, and plug it in a mains
socket.
¼
If you have used the internal screw terminals for power supply, the mains adapter
must not be connected.
• For a brief moment, all display segments will appear and the CO
2
 meter emits a signal
sound. Then the display shows „WARM UP“.
• The CO
2
 meter now needs approx. 1 minute for warm-up. During this time, all buttons
are deactivated.
In this time, the first CO
2
 concentration measurement is performed. The display also
indicates humidity and temperature.
Wait until warming up is completed and the „WARM UM“ display disappears.
• The CO
2
 meter is now ready for operation.
¼
If the CO
2
 meter measures a CO
2
 concentration exceeding 1200ppm after warm-up
(e.g. in an office room), the red LED lights up.
A signal sound may also be emitted (depending on factory settings) to indicate that
the upper threshold value was exceeded. To activate signal sound muting, see
chapter 10. a).
The yellow LED lights up at a CO
2
 concentration between 800 and 1200ppm.
To programme new threshold values for the CO
2
 measurement, proceed as
described in chapters 9 b) and 9 c).
Also set the correct altitude at the installation site (barometric pressure
compensation, see chapter 9 d).