Testo testo 870-2 , 9 Hz thermography camera, , 160 × 120 pix bolometer matrix 0560 8702 ユーザーズマニュアル

製品コード
0560 8702
ページ / 32
5 Performing the measurement 
21 
The following table gives typical emissivities of important materials. These 
values can be used as a guide for user-defined settings.  
Material (material temperature) 
Emissivity 
Aluminium, bright rolled (170 °C) 
0.04 
Cotton (20 °C) 
0.77 
Concrete (25 °C) 
0.93 
Ice, smooth (0 °C) 
0.97 
Iron, emery-ground (20 °C) 
0.24 
Iron with casting skin (100 °C) 
0.80 
Iron with rolling skin (20 °C) 
0.77 
Gypsum (20 °C) 
0.90 
Glass (90 °C) 
0.94 
Rubber, hard (23 °C) 
0.94 
Rubber, soft grey (23 °C) 
0.89 
Wood (70 °C) 
0.94 
Cork (20 °C) 
0.70 
Radiator, black anodised (50 °C) 
0.98 
Copper, slightly tarnished (20 °C) 
0.04 
Copper, oxidised (130 °C) 
0.76 
Plastics: PE, PP, PVC (20 °C) 
0.94 
Brass, oxidised (200 °C) 
0.61 
Paper (20 °C) 
0.97 
Porcelain (20 °C) 
0.92 
Black paint, matt (80 °C) 
0.97 
Steel, heat-treated surface (200 °C) 
0.52 
Steel, oxidised (200 °C) 
0.79 
Clay, burnt (70 °C) 
0.91 
Transformer paint (70 °C) 
0.94 
Brick, mortar, plaster (20 °C)  
0.93 
 
 
Reflected temperature information: 
Using this offset factor, the reflection is calculated out based on the low 
emissivity, and the accuracy of the temperature measurement with infrared 
measuring instruments is improved. In most cases, the reflected temperature is 
identical to the ambient air temperature. Only when objects with strong 
emissions at much lower temperatures (such as cloudless skies during outdoor 
readings) or much higher temperatures (such as ovens or machines) are in 
proximity to the object being measured should the radiation temperature of