Step 2. 
Internal Clock (Asynchronous Clock) 
Click on Internal Clock, and then select the Frequency from the pull down 
menu to set up the frequency of the device under test (DUT). The frequency 
of the Internal Clock must be at least four times higher then the frequency 
of the Oscillator on the DUT. Or,    select the frequency 
  from 
the pull down menu on Tool Bar as Fig 3-2 shows. 
Tip:
  Connect the signal output pin of the tested board to the Signal connector of 
Logic Analyzer to measure it using the internal clock of Logic Analyzer. 
 
 
Fig 2-2 – Clock source drop down menu 
External Clock (Synchronous Clock) 
Click on External Clock, and then select 
Rising Edge
 or 
Falling Edge
 as the 
trigger condition of the DUT. In the Frequency column, type the frequency of 
the oscillator on the DUT.   
Tip:
  The  External  Clock  is  applied  when  the  frequency  of  the  oscillator  on  the 
tested board is less then 100MHz. Connect the output pin of oscillator on the 
tested board to the CLK pin of Logic Analyzer as shown in Fig 3-3.