Intel Desktop Board D865PERL BLKD865PERLK ユーザーズマニュアル
製品コード
BLKD865PERLK
Technical Reference
81
Figure 30 shows the locations of the localized high temperature zones.
OM15903
B
A
D
C
Item Description
A
Processor voltage regulator area
B Processor
C Intel 82865PE MCH
D Intel 82801EB ICH5 or 82801ER ICH5-R
Figure 30. Localized High Temperature Zones
Table 45 provides maximum case temperatures for components on the Desktop Board D865PERL
that are sensitive to thermal changes. The operating temperature, current load, or operating
frequency could affect case temperatures. Maximum case temperatures are important when
considering proper airflow to cool the Desktop Board D865PERL.
that are sensitive to thermal changes. The operating temperature, current load, or operating
frequency could affect case temperatures. Maximum case temperatures are important when
considering proper airflow to cool the Desktop Board D865PERL.
Table 45. Thermal Considerations for Components
Component
Maximum Case Temperature
Intel Pentium 4 processor
For processor case temperature, see processor datasheets and
processor specification updates
processor specification updates
Intel
82865PE MCH
99
o
C (under bias)
Intel 82801EB ICH5 or
82801ER ICH5-R
82801ER ICH5-R
115
o
C (under bias)
For information about
Refer to
Intel Pentium 4 processor datasheets and specification updates
Section 1.2, page 16