HP ProLiant DL120 G5 E2160 1.8GHz Dual Core Non-Hot Plug SATA Rack Server 465475-421 ユーザーズマニュアル

製品コード
465475-421
ページ / 32
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment. Noise
emissions were measured in accordance with ISO 7779 (ECMA 74) and
declared in accordance with ISO 9296 (ECMA 109).
Idle
 
LWAd
6.26 B
LpAm
43.8 dBA
Operating
 
LWAd
6.28 B
LpAm
44.5 dBA
Emissions Classification
(EMC)
FCC Rating
Class A
Normative Standards
CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254;
K22;K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1
NOTE: Product conformance to cited product specifications is based on
sample (type) testing, evaluation, or assessment. This product or family of
products is eligible to bear the appropriate compliance logos and statements.
Power Supply
Input voltage
specifications
Rated input voltage
100 VAC to 240 VAC
Input Specifications
Rated input line
90 VAC to 264VAC
Frequency range
47 to 63 Hz
Rated input power
@ 115V input, Rated input power = 500W
(assume output wattage=350W
@ 230V input, Rated input power = 500W
(assume output wattage=350W)
Rated input current
6 A, 3 A (110 V, 220 V)
Steady state power
350W (rated)
BTU Rating
1710 BTU/hr
 
Ambient temperature
range
Operating
50° to 118° F (10° to 48° C)
Non-operating
-40° to 158° F (-40° to 70° C)
Relative humidity
(non-condensing)
Operating
55% to 85%
Non-operating
5% to 95%
Dielectric voltage
withstand
Input to output
 
Input to ground
 
Maximum Wet Bulb
Temperature
106.3° F (41.3° C)
 
QuickSpecs
HP ProLiant DL120 Generation 5
Technical Specifications
DA - 13014   Worldwide QuickSpecs — Version 15 — 4.27.2009
Page 30