Fluke 190-104/EU 4-channel hand-held oscilloscope, ScopeMeter® 190 series II, hand-held 3894540 ユーザーズマニュアル

製品コード
3894540
ページ / 140
 
 
 
Safety Information: Read First 
 
  
 Warning 
To avoid electrical shock or fire if a product 
input is connected to more than 42 V peak 
(30 Vrms) or 60 V dc: 
• Use only insulated voltage probes, test leads 
and adapters supplied with the product, or 
indicated by Fluke as suitable for the Fluke 
190-104 and 190-204 ScopeMeter series. 
• Before use, inspect voltage probes, test leads 
and accessories for mechanical damage and 
replace when damaged. 
• Remove all probes, test leads and 
accessories that are not in use. 
• Always connect the power adapter first to the 
ac outlet before connecting it to the product. 
• Do not touch voltages >30 V ac rms, 42 V ac 
peak, or 60 V dc. 
• Do not connect the ground spring (figure 1, 
item d) to voltages higher than 42 V peak 
(30 Vrms) from earth ground. 
• Do not apply more than the rated voltage, 
between the terminals or between each 
terminal and earth ground. 
• Do not apply input voltages above the rating 
of the instrument. Use caution when using 
1:1 test leads because the probe tip voltage 
will be directly transmitted to the product. 
• Do not use exposed metal BNC connectors. 
Fluke offers cables with plastic, safety 
designed BNC connectors suitable for the 
ScopeMeter product, see Chapter 7 ‘Optional 
accessories’. 
• Do not insert metal objects into connectors. 
• Use the product only as specified, or the 
protection supplied by the product can be 
compromised. 
• Carefully read all instructions. 
• Do not use the product if it operates 
incorrectly. 
• Do not use and disable the product if it is 
damaged. 
• Keep fingers behind the finger guards on the 
probes. 
• Use only correct measurement category 
(CAT), voltage, and amperage rated probes, 
test leads, and adapters for the measurement.