4.3 
Firmware updates
4.3.1  Update of the control panel unit (HMI)
The control panel (HMI) can be updated via the front or back USB ports, whereby the back USB port requires a 
PC with suitable software and the front USB needs only a FAT32 formatted USB stick with the update file. Hence 
the latter option is much simpler.
Firmware updates should only be installed when they can eliminate existing bugs in the 
firmware in the device or contain new features. 
 
► How to update the control panel firmware:
1. 
If not already available, obtain a USB flash drive (capacity up to 32GB) and ensure that it is formatted as 
FAT32.
2. 
Create a folder with the name HMI_FILES (case sensitive!) in the root directory of the flash drive and copy 
the firmware update file to this folder. The file name must follow the begin with “update_hmi” (example: 
update_hmi_v100.bin) or with a number (example: 96230058_FW-BE1_V201.bin).
3. 
Tap the touch area 
, then HMI SETTINGS, then HMI UPDATE and confirm the security question 
with ENTER. The HMI will then read and list the contents of the HMI_FILES folder.
4. 
Select and tick the update file to be used and tap the touch area LOAD FROM USB. The control panel will 
then be updated.
5. 
Switch the equipment off, wait until it is completely off (fan not running anymore), then switch back on.
4.3.2  Update of the interface unit (KE)
The firmware of the device, if necessary, is updated via the rear side USB port. For this a software, a so-called 
“update tool” is needed which is available from EA Elektro-Automatik (as download from the website or upon re-
quest), together with the firmware update. The update tool guides the user through the update process.
In case the update tool is not available, or if the update somehow went wrong and the device will not work correctly, 
there is an alternative procedure. Required tools: 1x Sub-D plug 15-pole, some wire, solder iron, update file (*.bin).
 
► How to manually update the device firmware:
1. 
Power off device. If not already available, prepare the 15 pole D-Sub plug like this (figure shows backside):
Bridge between pin 5 and 6
Bridge between pin 13 and 14
2. 
Plug the Sub-D onto the analog interface socket and connect the (included) USB-B cable between the USB 
port on the rear and the PC. Switch device on by mains switch.
3. 
The PC should mount a new removable drive named “UPDATE”, for example with driver lett G:. If not, wait 
some time and repeat steps 1 and 2.
4. 
Open that new drive in a suitable software, like Windows Explorer. It should contain one file “firmware.bin”. 
Delete the file.
5. 
Copy the new firmware file, which always has to be with extension *.bin, to that drive. Wait for the copy 
procedure to finish.
6. 
Switch the device off and remove the Sub-D plug from the analog interface socket.
7. 
Restart the device by switching it on - the display shows some information during the startup process, 
amongst them the new device firmware version as for example “KE: 2.09”.