Kuebler Kübler CODIX 520 Pulse timer Codix 520 Assembly dimensions 45 x 22 mm 6.520.012.300 データシート

製品コード
6.520.012.300
ページ / 8
4
4.3 Decimal point
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0
 one decimal place
0.00  two decimal places
0.000 three decimal
places
Operating instructions
Electronic totaliser
CODIX 520
1. Description
•  6digit adding counter, resetable
•  LED-Display with 8 mm high characters and
very high luminosity
•  Display range 0..999999 (overflow condition will
be indicated by displaying the count value
without leading zero blanking. The display
restarts at 0.)
•  Programming of count functions and operating
parameters via the setting keys. During
programming the display guides the user with
text prompts.
•  Programmable features:
Input polarity (npn or pnp)
Max. count frequency (30 Hz or 20 kHz)
Decimal point
Reset mode:
electrical
manual
manual and electrical
no reset
2. Inputs
INP
Dynamic count input. Max. count frequency 30 Hz
or 20 kHz programmable via set up
RESET
Dynamic reset input. Linked to the red reset key.
3. Setting of the operating
parameters
a. Hold down keys on front panel and switch on
the supply voltage.
b. The display shows
c. After releasing the keys the display alternates
between menu title and corresponding menu
item at a frequency of 0.5 Hz. After any key is
pressed down, only the menu item is displayed.
d. Pressing the right key, the menu item will be
switched to next value.
e. Hold down the left key and press the right key
to switch to the next menu title.
f. After programming the last menu item, the
programming routine will be left and the new
values will be stored by switching the menu
item to „YES“.  If you chose „NO“, the
programming routine will be passed through
once again.
4.1 Input polarity
npn: switching to 0 V
pnp: switching to +24 V
4.2 Activating the 30 Hz filter
max. count frequency
20 kHz
max. count frequency
30 Hz
4.4 Reset mode
manual reset (red key)
and electrical reset
no reset
(red key and reset input
locked)
electrical reset only
manual reset only
4. Programming routine
Programmable parameters are shown in
succession. After one pass, the device is fully
programmed.
In each case the first shown item is the factory
preset.
- Subject to change without prior notice -