Analog Devices ADP1046A Evaluation Board ADP1046ADC1-EVALZ ADP1046ADC1-EVALZ データシート

製品コード
ADP1046ADC1-EVALZ
ページ / 48
UG-320 
Evaluation Board User Guide 
 
Rev. A | Page 16 of 48 
10180-
013
 
Figure 14. Fan Connection to Cool Heat Sink, Transformers, and Inductors 
FAN CONTROL 
The OUTAUX PWM is used to control an external fan 
connected to Connector J19. The average speed of the fan 
depends on the load. The PWM input to the fan is duty cycle 
modulated and is programmed with the main PWM output in a 
manner that provides the maximum speed at maximum load 
and vice versa. Note that the fan is not included in the kit. 
DYNAMIC PHASE SHEDDING AND STANDBY 
POWER 
Dynamic phase shedding is achieved using the light load feature 
of the 
. This setting is programmed to activate within 
75 µs of detecting the output current via the CS2+ and CS2− 
pins. The IC is programmed to enter dual phase mode at 60% of 
the full load current and automatically turns off the PWMs for 
the second phase when the load current is less than approxi-
mately 54% of the full load current. 
Using an external microcontroller to communicate to the IC, 
the 
 can also disable the synchronous rectifiers and 
save more power at no load by entering the pulse skipping 
mode, where the entire PWM pulse is skipped if the required 
duty cycle is less than the programmed value.