C Control PRO MINI STATION 198777 データシート

製品コード
198777
ページ / 28
12
m) Description of the Connection Clamps
"X1" Strip terminal
Inputs
Function
Voltage range
+UB
Supply voltage (+)
9 - 16V/DC, 200mA
GND
Supply voltage (-)
Ground
ADC0
PA.0 / analogue input / 1 wire
0 - 5V/DC
ADC1
PA.1 / analogue input / 1 wire
0 - 5V/DC
INPUT1
PD.3 / external interrupt1 / INT1
0 - 16V/DC
INPUT2
PD.6 / Input capture pin for pulse / period measurem.
0 - 16V/DC
INPUT3
PB.0 / Input Timer/Counter0  / T0
0 - 16V/DC
INPUT4
PB.1 / Input Timer/Counter1  / T1
0 - 16V/DC
INPUT5
PD.2 / external interrupt2 / INT2
0 - 16V/DC
"X2" Strip terminal
Outputs
Function
Technical Data
+5V
Output (+) e.g. for I/Os
Max. 30mA (limited)
GND
Output (-)
Ground
OUTPUT1
PB.3 / Output Timer0 / OT0
max. +5V / 10mA DC
OUTPUT2
PC.3
max. +5V / 10mA DC
OUTPUT3
PC.2
max. +5V / 10mA DC
OUTPUT4
PC.1 / I2C-Interface SDA / 1 Wire
max. +5V / 10mA DC
OUTPUT5
PC.0 / I2C-Interface SCL / 1 Wire
max. +5V / 10mA DC
OUTPUT6
PD.5 / Output A Timer1 / OT1A
max. +5V / 10mA DC
OUTPUT7
PD.4 / Output B Timer1 / OT1B
max. +5V / 10mA DC
The red LEDs at the outputs ("OUTPUT1" to "OUTPUT5") indicate the switching
state of terminal strip X2. When the red LED is lit, the respective output has a
high level (+5V).