Atmel Xplained Pro Evaluation Kit ATSAM4E-XPRO ATSAM4E-XPRO データシート
![Atmel](https://files.manualsbrain.com/attachments/0369829915bda09f9c2e00fb805a7753579683b5/common/fit/150/50/8d2bf08978ec3e5bc63f4343ac5e91ce8d0e40045619fa520d910d64af8f/brand_logo.png)
製品コード
ATSAM4E-XPRO
SAM4E [DATASHEET]
Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
370
18.5.3 Reinforced Safety Watchdog Timer Status Register
Name:
RSWDT_SR
Address:
0x400E1908
Access:
Read-only
WDUNF: Watchdog Underflow
0: No watchdog underflow occurred since the last read of RSWDT_SR.
1: At least one watchdog underflow occurred since the last read of RSWDT_SR.
WDERR: Watchdog Error
0: No watchdog error occurred since the last read of RSWDT_SR.
1: At least one watchdog error occurred since the last read of RSWDT_SR.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
–
–
–
–
–
–
WDERR
WDUNF