Figure 39-3.
Clock Selection
39.6.4 Clock Control
The clock of each counter can be controlled in two different ways: it can be enabled/disabled and started/stopped.
See 
.
The clock can be enabled or disabled by the user with the CLKEN and the CLKDIS commands in the TC 
Channel Control Register (TC_CCR). In Capture Mode it can be disabled by an RB load event if LDBDIS is set 
to 1 in the TC_CMR. In Waveform Mode, it can be disabled by an RC Compare event if CPCDIS is set to 1 in 
TC_CMR. When disabled, the start or the stop actions have no effect: only a CLKEN command in the 
TC_CCR can re-enable the clock. When the clock is enabled, the CLKSTA bit is set in the TC_SR.
The clock can also be started or stopped: a trigger (software, synchro, external or compare) always starts the 
clock. The clock can be stopped by an RB load event in Capture Mode (LDBSTOP = 1 in TC_CMR) or a RC 
compare event in Waveform Mode (CPCSTOP = 1 in TC_CMR). The start and the stop commands have effect 
only if the clock is enabled.
TIMER_CLOCK1
TIMER_CLOCK2
TIMER_CLOCK3
TIMER_CLOCK4
TIMER_CLOCK5
XC0
XC1
XC2
TCCLKS
CLKI
Synchronous
Edge Detection
BURST
Peripheral Clock
1
Selected
Clock