Atmel SAM4S-XPLD Atmel ATSAM4S-XPLD ATSAM4S-XPLD データシート
![Atmel](https://files.manualsbrain.com/attachments/0369829915bda09f9c2e00fb805a7753579683b5/common/fit/150/50/8d2bf08978ec3e5bc63f4343ac5e91ce8d0e40045619fa520d910d64af8f/brand_logo.png)
製品コード
ATSAM4S-XPLD
919
SAM4S [DATASHEET]
11100E–ATARM–24-Jul-13
• CES: Counter Event Selection
).
CALG = 0 (Left Alignment):
0/1 = The channel counter event occurs at the end of the PWM period.
CALG = 1 (Center Alignment):
0 = The channel counter event occurs at the end of the PWM period.
1 = The channel counter event occurs at the end of the PWM period and at half the PWM period.
• DTE: Dead-Time Generator Enable
0 = The dead-time generator is disabled.
1 = The dead-time generator is enabled.
• DTHI: Dead-Time PWMHx Output Inverted
0 = The dead-time PWMHx output is not inverted.
1 = The dead-time PWMHx output is inverted.
• DTLI: Dead-Time PWMLx Output Inverted
0 = The dead-time PWMLx output is not inverted.
1 = The dead-time PWMLx output is inverted.