Manchester Code Library
mikroBasic PRO for dsPIC30/33 and PIC24 provides a library for handling Manchester coded signals. The Manchester 
code is a code in which data and clock signals are combined to form a single self-synchronizing data stream; each 
encoded bit contains a transition at the midpoint of a bit period, the direction of transition determines whether the bit 
is 0 or 1; the second half is the true bit value and the first half is the complement of the true bit value (as shown in the 
figure below).
Important
- The Manchester receive routines are blocking calls (
Man_Receive_Init 
and
 Man_Synchro
). This means that  
  MCU will wait until the task has been performed (e.g. byte is received, synchronization achieved, etc). 
- Manchester code library implements time-based activities, so interrupts need to be disabled when using it. 
The following variables must be defined in all 
projects using Manchester Code Library:
Description:
Example:
dim MANRXPIN as sbit sfr external
Receive line.
dim MANRXPIN as sbit at RF0_bit
dim MANTXPIN as sbit sfr external
Transmit line.
dim MANTXPIN as sbit at LATF1_bit
dim  MANRXPIN_Direction  as  sbit  sfr 
external
Direction of the Receive pin.
dim  MANRXPIN_Direction  as  sbit  at 
TRISF0_bit
dim  MANTXPIN_Direction  as  sbit  sfr 
external
Direction  of  the  Transmit 
pin.
dim  MANTXPIN_Direction  as  sbit  at 
TRISF1_bit
External dependencies of Manchester Code Library