Mikroelektronika MIKROE-724 データシート
mikroBasic PRO for dsPIC30/33 and PIC24
MikroElektronika
381
Manchester Code Library
mikroBasic PRO for dsPIC30/33 and PIC24 provides a library for handling Manchester coded signals. The Manchester
code is a code in which data and clock signals are combined to form a single self-synchronizing data stream; each
encoded bit contains a transition at the midpoint of a bit period, the direction of transition determines whether the bit
is 0 or 1; the second half is the true bit value and the first half is the complement of the true bit value (as shown in the
figure below).
Important:
- The Manchester receive routines are blocking calls (
Man_Receive_Init
and
Man_Synchro
). This means that
MCU will wait until the task has been performed (e.g. byte is received, synchronization achieved, etc).
- Manchester code library implements time-based activities, so interrupts need to be disabled when using it.
The following variables must be defined in all
projects using Manchester Code Library:
Description:
Example:
dim MANRXPIN as sbit sfr external
Receive line.
dim MANRXPIN as sbit at RF0_bit
dim MANTXPIN as sbit sfr external
Transmit line.
dim MANTXPIN as sbit at LATF1_bit
dim MANRXPIN_Direction as sbit sfr
external
Direction of the Receive pin.
dim MANRXPIN_Direction as sbit at
TRISF0_bit
dim MANTXPIN_Direction as sbit sfr
external
Direction of the Transmit
pin.
dim MANTXPIN_Direction as sbit at
TRISF1_bit
External dependencies of Manchester Code Library