mikoBasic PRO for dsPIC30/33 and PIC24
MikroElektronika
SPI_Ethernet_UserTCP
Prototype
sub function SPI_Ethernet_UserTCP(dim remoteHost as ^byte, dim remotePort 
as word, dim localPort as word, dim reqLength as word, dim byref flags as 
TEthPktFlags) as word
Description This is TCP module routine. It is internally called by the library. The user accesses to the TCP request 
by using some of the SPI_Ethernet_get routines. The user puts data in the transmit buffer by using 
some of the SPI_Ethernet_put routines. The function must return the length in bytes of the TCP reply, 
or 0 if there is nothing to transmit. If there is no need to reply to the TCP requests, just define this 
function with return(0) as a single statement.
Parameters 
remoteHost
: client’s IP address. 
remotePort
: client’s TCP port. 
localPort
: port to which the request is sent. 
reqLength
: TCP request data field length. 
flags
: structure consisted of two bit fields:  
Copy Code To Clipboard 
structure TEthPktFlags
  dim canCloseTCP as boolean  ‘ flag which closes socket
  dim isBroadcast as boolean ‘ flag which denotes that the IP package has 
been received via subnet broadcast address
end structure
Returns
0
 - there should not be a reply to the request. 
- Length of TCP reply data field - otherwise. 
Requires
Ethernet module has to be initialized. See SPI_Ethernet_Init.
Example
This function is internally called by the library and should not be called by the user’s code.
Notes
The function source code is provided with appropriate example projects. The code should be adjusted 
by the user to achieve desired reply.
SPI_Ethernet_getBytes
Prototype
sub procedure SPI_Ethernet_getBytes(dim ptr as ^byte, dim addr as word, dim 
n as word)
Description This is MAC module routine. It fetches equested number of bytes from 
ENC28J60
 RAM starting from 
given address. If value of 
0xFFFF
 is passed as the address parameter, the reading will start from 
current 
ENC28J60
 read pointer (
ERDPT
) location.
Parameters 
ptr
: buffer for storing bytes read from 
ENC28J60
 RAM. 
addr
ENC28J60
 RAM start address. Valid values: 
0..8192
n
: number of bytes to be read. 
Returns
Nothing.
Requires
Ethernet module has to be initialized. See SPI_Ethernet_Init.
Example
dim 
  buffer as byte[16] 
  ...
  SPI_Ethernet_getBytes(buffer, 0x100, 16) ‘ read 16 bytes, starting from 
address 0x100
Notes